Connect Vent - Maytag MGT3800XW1 Installation Instructions Manual

27"(69cm) gas washer/dryer
Table of Contents

Advertisement

Available languages

Available languages

r_KE
GAS
CONNECTION
1,
Connecting
gas supply to dryer
A. Flared male
fitting
B. Non-flared
male fitting
A
...........
......
S
Remove red cap from flexible gas connector. Remove the
1/2" NPT adapter from the flexible gas connector (it will be
necessary to use two adjustable wrenches). Using a wrench
to tighten, connect gas supply to washer/dryer.
Use pipe-
joint compound
on threads of all non-flared male fittings.
If flexible metal tubing is used, be sure there are no kinks.
NOTE: For LP gas connections,
you must use pipe-joint
compound
resistant to action of LP gas. Do not use
TEFLON ®t tape.
2.
Install
adapter
A. 1/2" rigid gas supply
pipe
B. Use pipe-joint
compound.
C.1/2" NPT adapter
D. Do not use pipe-joint
compound.
E. Flexible gas
connector
E
Install the adapter on the 1/2" rigid gas supply pipe using
pipe-joint compound.
NOTE: For LP gas connections,
you must use pipe-joint
compound
resistant to action of LP gas. Do not use
TEFLON ®t tape.
3.
Attach
connector
. ofo
_
_
_
WRONG
_
CORRECT
,%
_
Attach the flexible gas connector to the 1/2" NPT adapter.
Do not use pipe-joint compound for this connection.
There should be a natural loop in the flexible gas connector.
The flexible gas connector must not be twisted, kinked, or
attached with any sharp bends.
1®TEFLON
is a registered
trademark
of E.I. Dupont De Nemours and Company.
18
4.
Open shut=off
valve
A. Closed valve
B. Open valve
Open shut-off valve in supply line; valve is open when handle
is parallel to gas pipe. Then, test all connections
by brushing
on an approved noncorrosive
leak-detection
solution.
Bubbles will show a leak. Correct any leak found.
CONNECT
¥_NT
Using a 4" (102 mm) clamp, connect vent to exhaust outlet
in dryer. If connecting to existing vent, make sure vent is
clean. Dryer vent must fit over dryer exhaust outlet and inside
exhaust hood. Check that vent is secured to exhaust hood
with a 4" (102 mm) clamp.
2.
Move washer/dryer
to final
location
Move washer/dryer
to final location, taking care not to crush
or kink vent.
After washer/dryer
is in place, remove corner posts and
cardboard from under washer/dryer.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mgt3800xw0Mgt3800xw2Wgt3300xq1Wgt3300xq2