Electrical Requirements - Thermador HMWB30 Installation Manual

Ventilation hood
Hide thumbs Also See for HMWB30:
Table of Contents

Advertisement

Available languages

Available languages

IMPORTANT SAFETY INSTRUCTIONS
Read All Instructions
Before Using the Appliance.
READ AND SAVE THESE INSTRUCTIONS
Electrical
requirements
IMPORTANT
Observe
all governing
codes and ordinances.
It is the customer's
responsibility:
To contact a qualified
electrical
installer.
To assure
thatthe
electrical
installation is adequate
and in conformance
with National
Electrical
Code,
ANSI/NFPA
70 -- latest edition s-,or CSA Standards
C22.1-94,
Canadian
Electrical
Code,
Part land
C22.2
No.0-M91
- latest edition_-_-and all local
codes and ordinances.
If codes
permit and a separate
ground wire is used,
iris recommended
that a qualified
electrician
determine
that the ground
path is adequate.
Do notground
to a gas pipe.
Check with a qualified
electrician
if you are not sure
range hood is properly
grounded.
Do not have a fuse in the neutral
or ground
circuit.
IMPORTANT
Save Installation
Instructions
for electrical
inspector's
use.
The range
hood must be connected
with copper
wire only.
The range
hood should
be connected
directly
to the
fused disconnect
(or circuit breaker)
box through
metal electrical
conduit.
Wire sizes must conform to the requirements
of the
National
E lectrical
Code ANSI/NFPA 70--latest
edition s-,or CSA Standards
C22.1-94,
Canadian
Electrical
Code Part 1 and C22.2
No. 0-M91 - latest
edition_-_-and all local codes and ordinances.
A U.L. - or C.S.A. - listedconduit
connector
must be
provided
at each end of the power supply conduit
(at the range hood and at the junction
box).
Copies
of the standards
listed
may be obtained
from:
National
Fire
Protection
Association
Batterymarch
Park
Quincy,
Massachusetts
02269
_CSA
International
8501 East
Pleasant
Valley
Road
Cleveland,
Ohio
44131-5575
4