Table 5-2
Table 5-3
Display Signals on the System Board – All Oscilloscopes
Signal
Name
J2300 Pin 14
Hsync
J2300 Pin 13
Vsync
Low Voltage Power Supply Tolerances
Supply Voltage
Tolerance
+5.1 V
±153 mV (+4.947 V to +5.253 V)
-5.2 V
±156 mV (-5.04 V to -5.36 V)
+15.75 V
+1.260 V, -787 mV (+14.963 V to +17.010 V)
+3.4 V
±100 mV (+3.30 V to +3.50 V)
To check out the oscilloscope
Frequency
Pulse Width
19.72 kHz
3.0 ms
60.00 Hz
253.5 ms
Troubleshooting
Voltage
4.5 V
p-p
4.5 V
p-p