Download Print this page

Grounding Instructions - Whirlpool YGEQ9800PW1 Installation Instructions Manual

27 in. (69cm) electric dryer
Hide thumbs Also See for YGEQ9800PW1:

Advertisement

Available languages

Available languages

• Companion
appliance spacing should a lso beconsidered.
m
L_
{73.66
cm}
(25 cm)
(25 cm) (705
cm) {14 cm)
1
2
m
48"z
_
(310 cm_}-
24"2
(155 crn2}_
_.
-3"
(76 cm)
'3"
(76 cm)
7
1, Recessed area
2. Side view - closet or confined area
3. Closet door with vents
Mobile Home-Additional
Installation
Requirements
This dryer is suitable for mobile home installations. The installation
must conform to the Canadian Manufactured Home Standard,
CAN/CSA-Z240
MH.
Mobile home installations require:
Metal exhaust system hardware which is available for
purchase from your dealer.
Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such as a
nearby window) should be at least twice as large as the dryer
exhaust opening.
Electrical
Shock Hazard
Plug into a grounded
4 prong outlet.
Failure to do so can resumt in death or electrica_ shock.
It is your responsibility
To contact a qualified electrical installer.
To be sure that the electrical connection is adequate and in
conformance with the Canadian Electrical Code, C22.1-1atest
edition and all local codes. A copy of the above codes
standard may be obtained from: Canadian Standards
Association, 178 Rexdale Blvd., Toronto, ON M9W 1R3
CANADA.
To supply the required 4 wire, single phase, 115/230-volt,
60-
Hz., AC-only electrical supply on a separate 30-amp circuit,
fused on both sides of the line. A time-delay fuse or circuit
breaker is recommended.
Connect to an individual branch
circuit.
This dryer is equipped with a CSA International Certified
Power Cord intended to be plugged into a standard 14-30R
wall receptacle. The cord is 5 ft (1.52 m) in length. Be sure wall
receptacle is within reach of dryer's final location.
4-wire receptacle
14-30R
Do not use an extension cord.
If using a replacement power supply cord, it is recommended
that
you use Power Supply Cord Replacement Part Number 9831317.
For further information, please reference the service numbers
located in your "Dryer User Instructions."
GROUNDING INSTRUCTIONS
[] For a grounded, cord-connected
dryer:
This dryer must be grounded, in the event of malfunction
or breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current. This
dryer is equipped with a cord having an equipment-grounding
conductor and a grounding plug. The plug must be plugged
into an appropriate outlet that is properly installed and ground-
ed in accordance with all local codes and ordinances.
WARNING;
improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative or
personnel if you are in doubt as to whether the dryer is proper-
ly grounded. Do not modify the plug provided with the dryer: if
it wilI not fit the outlet, have a proper outlet installed by a
qualified electrician.
SAVE THESE INSTRUCTIONS