Whirlpool GS440LEMT2 Installation Instructions And Operation Manual page 7

30" (76.2 cm) freestanding gas ranges

Advertisement

Available languages

Available languages

Fmexib_emetal appliance
connector:
[]
if local codes permit, a new A.GaA./CaSaA.design-certified,
4 - 5 ft (122 - 152.4 cm) long, !/2" (1.3 cm) ors/4'' (1.9 cm) LD.
flexible metal appliance connector may be used for
connecting range to the gas supply line.
[]
A 1/2"(1.3 cm) male pipe thread is needed for connection to
the female pipe threads of the inlet to the appliance gas
pressure regulator.
[]
Do not kink or damage the flexible metal tubing when moving
the range.
Rigid pipe connection:
The rigid pipe connection requires a combination
of pipe fittings
to obtain an in-line connection to the range. The rigid pipe must
be level with the range connection. All strains must be removed
from the supply and fue! lines so range will be level and in line.
Burner
_nput Requirements
Input ratings shown on the model/serial rating plate are for
elevations up to 2,000 ft (609.6 m).
For elevations above 2,000 ft (60%6 m), ratings are reduced at a
rate of 4% for each 1,000 ft (304.8 m) above sea level (not
applicable for Canada).
Gas
Supply
Pressure
Testing
Line pressure testing
above 1/2psi gauge (14" WCP)
The range and its individual manual shutoff valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures greater than
1Apsi (3.5 kPa).
Line pressure testing
at 1/_psi gauge (14" WCP) or _ower
The range must be isolated from the gas supply piping system by
dosing its individual manual shutoff valve during any pressure
testing of that system at test pressures equal to or less than
1Apsi (3.5 kPa).
[]
Must include a shutoff valve:
The supply line must be equipped with a manua! shutoff
valve. This valve should be located in the same room but
external to the range. It should be in a location that allows
ease of opening and closing. Do not block access to shutoff
valve. The valve is for turning on or shutting off gas to the
range.
B
"_
_--=_. c /
A. Gas supp!y /ine
B. Shutoff valve "open" position
C. To range
Gas Pressure
Regulator
The gas pressure regulator supplied with this range must be
used. The inlet pressure to the regulator should be as follows for
proper operation:
Natura_ Gas:
Minimum pressure: 5" WCP
Maximum pressure: 14" WCP
LP Gas:
Minimum pressure: 11" WCP
Maximum pressure: 14" WCP
Contact local gas supplier if you are not sure about the inlet
pressure.