SPECIAL FEATURES: PARTICLE FILTER / CHECKING THE ADDITIVE PUMP
B1HP1UTC
IMPERATIVE: Respect the safety and cleanliness requirements.
[1] Manual pressure/vacuum pump
[2] Additive container
IMPERATIVE: Respect the safety and cleanliness requirements specific to HDi engines.
IMPERATIVE: For all operations on the additive circuit, wear protective goggles and gloves that are
resistant to hydrocarbons.
Place the vehicle on a lift.
Raise the vehicle
To test the flow of the additive pump :
Uncouple the tube (1).
Couple tool [2] on the outlet «a» of the additive reservoir.
Operate for 50 seconds the actuator test «Additive pump» with the aid of LEXIA or PROXIA.
IMPERATIVE: The volume collected by the tool [2] should be 20 ± 5 ml.
NOTE: Replace the additive pump if it is defective.
Couple the tube (1).
Operate the actuator test «Filling the tube: additive pump – additive injector», with the aid of LEXIA or
PROXIA.