Electrolux EW30GS65GB8 Installation Instructions Manual page 9

30" gas slide in range with sealed top burners
Hide thumbs Also See for EW30GS65GB8:
Table of Contents

Advertisement

Available languages

Available languages

3,Checkthe
Igniters
Operation of electric igniters should be checked after
range and supply line connectors have been carefully
checked for leaks and range has been connected to
electric power. To check for proper lighting:
1.Push in and turn a surface burner knob to the LITE
position. You will hear the igniter sparking.
2. The surface burner should light when gas is available
to the top burner. Each burner should light within four
(4) seconds in normal operation after air has been
purged from supply lines. Visually check that burner
has lit.
3.Once the burner lights, the control knob should be
rotated out of the LITE position.
There are separate ignition devices for each burner. Try
each knob separately until all burner valves have been
checked.
Burner Ca_
Burner Head
Figure 11
4. Adjust the "low" setting for regular surface burner
valves (Figure 12)
Be careful when performing this operation.
a. Push in and turn control to LITE until burner ignites.
b. Quickly turn knob to LOWEST POSITION.
c. If burner goes out, reset control to OFF.
d. Remove the surface burner control knob.
e. Insert a thin-bladed
screwdriver into the hollow valve
stem and engage the slotted screw inside. Flame size
can be increased or decreased with the turn of the
screw. Turn counterclockwise
to increase flame size.
Turn clockwise to decrease flame size. Adjust flame
until you can quickly turn knob from LITE to LOWEST
POSITION without extinguishing
the flame. Flame
should be as small as possible without going out.
Note: Air mixture adjustment is not required on surface
burners.
5. Adjust the "LOW" Setting of the Dual Burner
Surface Valve (Figure 12)
Note: On the dual valve the low setting of each portion
should be adjusted individually.
a. Push in and turn control to LITE until the rear portion
of the bridge burner ignites only.
b. Quickly
turn knob to LOWEST POSITION.
c. If burner goes out, reset control to OFF.
d. Remove the surface burner control knob.
e. The rear or outer portion of the burner flame size
can be increased or decreased with the turn of the
screw A. Use screw B to adjust the flame size of the
center portion of the burner. Turn counterclockwise
the screw to increase flame size. Turn clockwise the
screw to decrease flame size. Adjust flame until you
can quickly turn knob from LITE to LOWEST
POSITIONwithout
extinguishing the flame. Flame
should be as small as possible without
going out.
Note: Air mixture adjustment is not required on surface
burners.
CountercJockwise
increase
FJame
Clockwise
Decrease Flame

Advertisement

Table of Contents
loading

Table of Contents