Keating Of Chicago SERIES 2000 User Manual

Miraclean gas griddle
Hide thumbs Also See for SERIES 2000:

Advertisement

Quick Links

NUMBERS OF THIS MIRACLEAN
GRIDDLE IN THE SPACES PROVIDED.
IMPORTANT:
Keep a copy of your bill of sale. The date on the bill establishes the warranty period should
service be required. If service is performed, it is in your interest to obtain and keep all receipts. Keating
commercial griddles are not intended for household use.
The Owner's Guide provides specific operating instructions for your model. Use the Miraclean
Griddle only as instructed in this Owner's Guide.
CONTENTS:
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
DAMAGE IN SHIPMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
POSITIONING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
VENTILATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
NATIONAL CODE REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . .1
GAS CONNECTIONS AND PIPE SIZE . . . . . . . . . . . . . . . . . . . . . .2
FLEXIBLE GAS CONNECTIONS & QUICK
DISCONNECT DEVICES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
LEVELING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
STAND ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
LIGHTING INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
SHUTDOWN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
COOKING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-5
CLEANING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
*AS CONTINUOUS PRODUCT IMPROVEMENT OCCURS, SPECIFICATIONS MAY BE CHANGED WITHOUT NOTICE.
Keep this manual for training new personnel.
p a r t # 0 373 9 9
Users Manual
MIRACLEAN
SERIES 2000
READ AND SAVE THIS MANUAL FOR FUTURE REFERENCE.
RECORD THE MODEL AND SERIAL
. . . . . . . . . . . . . . . . . . . . . . .1
®
GAS GRIDDLE
SERIAL NO. ______________________________
®
GAS
MODEL NO. _____________________________
KEEP THESE NUMBERS FOR FUTURE REFERENCE.
AVOID SERVICE CHECKLIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
CLEANING CARE & CONDITIONING . . . . . . . . . . . . . . . . . . . . . . .7
THERMOSTAT CALIBRATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
SERVICE PARTS ORDERING . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-8
PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
TROUBLE SHOOT CHART . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
THERMOSTAT REMOVAL & REPLACEMENT . . . . . . . . . . . . .11-12
SERVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-13
®
Gas
. . . . . . . . . . . . . . . . . . . . . . .6-7
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
1-800-KEATING
www.keatingofchicago.com
g a s G r i d d l e 2 0 0 0
0 2 / 1 3

Advertisement

Table of Contents
loading

Summary of Contents for Keating Of Chicago SERIES 2000

  • Page 1: Table Of Contents

    Users Manual MIRACLEAN ® GAS GRIDDLE SERIES 2000 READ AND SAVE THIS MANUAL FOR FUTURE REFERENCE. RECORD THE MODEL AND SERIAL SERIAL NO. ______________________________ NUMBERS OF THIS MIRACLEAN ® MODEL NO. _____________________________ GRIDDLE IN THE SPACES PROVIDED. KEEP THESE NUMBERS FOR FUTURE REFERENCE.
  • Page 2 Purchaser should post in a prominent location instructions to be followed in the event the user smells gas. This information shall be obtained by consulting the local gas supplier. WARNING WARNING Improper installation, FOR YOUR SAFETY Burns Shock adjustment, alteration, service or maintenance Do not store or use can cause property...
  • Page 3: Introduction

    INTRODUCTION FIRST STEPS Instructions in this manual should be read thoroughly POSITIONING before attempting to operate this Miraclean ® Griddle. Keep appliance area free and clear of any All installation and service on Keating equipment must combustibles. Position the Miraclean ®...
  • Page 4: Gas Connections And Pipe Size

    GAS CONNECTIONS AND PIPE SIZE FLEXIBLE GAS CONNECTORS AND QUICK DIS- CONNECT DEVICES The Miraclean ® Griddle requires a standard gas pipe size of 3/4 inch (19mm) I.D. connection. The size of the For an appliance equipped with casters: gas supply pipe is very important if the pipe is too small The installation shall be made with a connector that you will have low gas pressure at the Miraclean ®...
  • Page 5: Stand Assembly

    ASSEMBLY INSTRUCTIONS FOR GRIDDLE STAND ON CASTERS (THERE IS NO TOP ON THIS STAND) PLACING MIRACLEAN ® GRIDDLE IN OPERATION (When all previous instructions have been completed). Check the serial plate to determine if the burner is set up for the proper type gas before connecting the quick- disconnect or piping from the building gas supply pipe.
  • Page 6: Lighting Instructions

    LIGHTING INSTRUCTIONS You can prove this to yourself by holding your hand MIRACLEAN ® GRIDDLE approximately 1/2" above the Miraclean ® Griddle plate. At this distance it is difficult to tell whether the Griddle (See lighting instructions plate attached to front of MIR- plate is hot or not.
  • Page 7: Cooking

    The Miraclean ® Griddle can be kept in 2. Cook as usual, but after each batch scrape the griddle in the work area completely clean, using perfect condition by using a razor the 4" wide scraper supplied by Keating. (This may blade griddle scraper to remove the be the only cleaning you will ever need.) film that is deposited from the products...
  • Page 8: Cleaning

    CLEANING THE CLEANING CABINET The front, back and sides of the cabinet should be kept MIRACLEAN® GRIDDLE clean for sanitary reasons. ® The surface of the MIRACLEAN Griddle is very CARE OF THE MIRACLEAN® SURFACE durable and with proper care, following the procedures The Miraclean ®...
  • Page 9: Avoid Service Checklist

    Miraclean ® Griddle, under warranty, needs repairs other than routine cleaning, you are requested to con- tact KEATING OF CHICAGO, INC. (1-800 KEATING). PARTS ORDERING THERMOSTAT CALIBRATION Parts may be ordered by part number by calling Keating at 1- 800-KEATING or your service company.
  • Page 10: Parts List

    PARTS LIST MIRACLEAN ® Griddle 2011 CONTROL PANEL SERIES 2000 CONTROL PANEL 6, 7, 8 Figure 6-2 ITEM DESCRIPTION ITEM DESCRIPTION CONTROL PANEL FRAME 1-800-KEATING CONTROL PANEL INSERT 1-800-KEATING GREASE DRAWER DIAL PLATE 200°- 500°F 060105 30" & 36" Deep 052505 THERMOSTAT 550°F...
  • Page 11 PARTS LIST (CONT.) MIRACLEAN ® Griddle Figure 6-3 Natural and Propane Gas Heating Systems ITEM DESCRIPTION PART NUMBER ITEM DESCRIPTION PART NUMBER SPARK IGNITION ASSEMBLY MAIN GAS PIPE (3/4”) REFERENCE ONLY SEE Item 4, Figure 6-2 STREET ELBOW (3/4”) 005738 THERMOPILE 022770 UNION...
  • Page 12: Service Diagnosis

    SERVICE DIAGNOSIS The following diagnosis is only to be used as a guide to qualified service personnel. Keating recommends that you use a qual- ified & licensed service company. (Equipment still under warranty requires it.) NOTE: To correctly and quickly diagnose the system, the chart below should be followed in sequential order. TROUBLE SHOOTING CHART PROBLEM PROBABLE CAUSE...
  • Page 13: Thermostat Removal & Replacement

    SERVICE 3. Snap the new switch into place and reconnect all wires. Servicing should only be performed by qualified & 4. Return the control panel to its normal position. licensed service companies. THERMOSTAT GAS VALVE REMOVAL AND REPLACEMENT REGULATOR ADJUSTMENT Lower the control panel by removing the mount- Recommended gas pressure at manifold ing screws.
  • Page 14 THERMOSTAT BULB PLACEMENT DETAIL MILLIVOLT CHECK (FOR QUALIFIED SERVICE TECHNICIANS ONLY) The millivolt valve is a thermopile self-powered combination gas control. Before checking the millivolt system, the following operations should be performed and observations made: 1. A genuine Keating millivolt thermostat should be used for millivolt operation. 2.
  • Page 15 B. THERMOPILE OUTPUT CHECK BEFORE REPLACING THERMOPILE CHECK MILLIVOLT READINGS (“B” Reading. Thermostat contacts OPEN - Main burner OFF.) THERMOPILE READINGS 1. Thermopile system - 325 millivolts minimum. If the mini- With all wires connected, with the pilot on and burners mum millivolt reading is not obtainable, readjust ther- off, the thermopile reading at the TP&THTP terminals mopile for maximum millivolt output.
  • Page 16: Wiring Diagram

    WHITE TO ˆTP˜ TERMINAL RED TO ˆTH/TP˜ ON GAS VALVE ON GAS VALVE TO ˆTH˜ ON GAS VALVE TO ˆTH/TP˜ ON GAS VALVE TO ˆPILOT˜ ON GAS VALVE GAS GRIDDLE WIRING DIAGRAM - SERIES 2000 CONTROL PANEL THERMOSTAT ON/OFF SWITCH...
  • Page 18 Please state the nature of the call; it will ensure speaking with the appropriate person. Have your serial and model number available when ordering parts. KEATING OF CHICAGO, INC. 8901 W. 50th Street, McCook, Illinois 60525-6001 Phone: (708) 246-3000 FAX: (708) 246-3100 Toll Free 1-800-KEATING (In U.S.

This manual is also suitable for:

Miraclean 2000 series

Table of Contents