Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Installation Instructions . . . . . . . . . . . . . . . . . . . . .1
Damage in Shipment . . . . . . . . . . . . . . . . . . . . . . . .1
Positioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
National Code Requirements . . . . . . . . . . . . . . . . .1
Gas Connections and Pipe Size . . . . . . . . . . . . . . .2
Flexible Gas Connections & Quick
Disconnect Devices . . . . . . . . . . . . . . . . . . . . . . .2
Leveling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Stand Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Lighting Instructions . . . . . . . . . . . . . . . . . . . . . . . .4
Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
This Owner's Guide provides specific operating instructions for your model.
*As continuous product improvement occurs, specifications may be changed without notice.
GasGrid 2000
10/08
037399
"Serving Those Who Serve The Very Best"
MIRACLEAN
GAS GRIDDLE
INSTALLATION MANUAL
SERVICE INSTRUCIONS
1-800-KEATING
www.keatingofchicago.com
®
2000
®
®
Griddle in the space provided below.
CONTENTS
Cooking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-5
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Preventative Maintenance . . . . . . . . . . . . . . . . . . . .7
Avoid Service Checklist . . . . . . . . . . . . . . . . . . . . .7
Cleaning Care & Conditioning . . . . . . . . . . . . . . . .7
Thermostat Calibration . . . . . . . . . . . . . . . . . . . . . .7
Service Parts Ordering . . . . . . . . . . . . . . . . . . . . .7-8
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-12
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . .13

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MIRACLEAN Miraclean 2000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Keating Of Chicago MIRACLEAN Miraclean 2000

  • Page 1: Table Of Contents

    ® ® Griddle in the space provided below. CONTENTS Cooking ....... . .4-5 Cleaning .
  • Page 2 Purchaser should post in a prominent location instructions to be followed in the event the user smells gas. This information shall be obtained by consulting the local gas supplier. WARNING Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death.
  • Page 3: Introduction

    24 inches (610mm) should be provided at the front of the Miraclean ® operation. Air for combustion enters the Miraclean Griddle from the bottom of the cabinet and the bottom of the control panel. DO NOT BLOCK BOTTOM OF MIRACLEAN GRIDDLE CABINET. DO NOT OBSTRUCT FLUE.
  • Page 4: Gas Connections And Pipe Size

    Miraclean Griddle manifold. Low gas pressure will cause slow recovery and/or delayed ignition. If you have a question about gas pipe size call your local gas company.
  • Page 5: Stand Assembly

    ASSEMBLY INSTRUCTIONS FOR GRIDDLE STAND ON CASTERS (THERE IS NO TOP ON THIS STAND) PLACING MIRACLEAN GRIDDLE IN OPERATION (When all previous instructions have been completed). Check the serial plate to determine if the burner is set up for the proper type gas before connecting the quick- disconnect or piping from the building gas supply pipe.
  • Page 6: Lighting Instructions

    1/2" above the Miraclean At this distance it is difficult to tell whether the Griddle plate is hot or not. It feels as though the Griddle plate is barely warm, but if you touch the plate, it will burn you.
  • Page 7: Cooking Procedures

    Griddle plate clean and shiny at all times. If an accumulation builds up on the Miraclean it is necessary only to wash it with a palmetto pot brush and cold water. As you pour water on the Griddle and MIRACLEAN ®...
  • Page 8: Cleaning

    The surface of the MIRACLEAN durable and with proper care, following the procedures below, will last many years. A sample of Keating Klenzer, Keating palmetto brush and a 4" scraper are included with each new griddle. Scrape MIRACLEAN ® surface.
  • Page 9: Preventative Maintenance

    Miraclean ® Griddle, under warranty, needs repairs other than routine cleaning, you are requested to contact KEATING OF CHICAGO, INC. (1-800 KEATING). THERMOSTAT CALIBRATION Calibration is not covered under warranty. Turn the exhaust system ON. Turn on the griddle with thermostat set at 300°F. Allow burners to cycle on and off three times.
  • Page 10: Item Description

    PROPANE ORIFICE BURNER INSERT BURNER AIR SHUTTERS MAIN SUPPLY GAS VALVE 3/4" (not shown above) PARTS LIST MIRACLEAN ® Griddle ITEM CONTRON PANEL FRAME GREASE DRAWER 30" & 36" Deep SWITCH, ROCKER SPARK IGNITER WITH ELECTRODE (NO BRACKET) CONTROL PANEL INSERT THERMOSTAT 400°F...
  • Page 11: Service Diagnosis/Trouble Shoot Chart

    NOTE: To correctly and quickly diagnose the system, the chart below should be followed in sequential order. PROBLEM No Pilot Pilot won’t stay on Pilot on but no main burner ignition Temperature of griddle erratic Griddle stays hot or overheats Burners will not shut off Flames pulsate. SERVICE DIAGNOSIS TROUBLE SHOOTING CHART PROBABLE CAUSE a.
  • Page 12: Thermostat Removal & Replacement

    4. Access the pipe union at the rear of the gas valve either from the front of the griddle or remove the back of the cabinet and loosen the union. 5. Remove two nuts on the rear of the gas manifold and pull the gas manifold forward.
  • Page 13 THERMOSTAT BULB PLACEMENT DETAIL MILLIVOLT CHECK (FOR QUALIFIED SERVICE TECHNICIANS ONLY) The millivolt valve is a thermopile self-powered combination gas control. Before checking the millivolt system, the following operations should be performed and observations made: 1. A genuine Keating millivolt thermostat should be used for millivolt operation. 2.
  • Page 14 ~500mv. With the burners on, the millvolt reading should be ~200mv. WARNING AND OPERATING PLATES All warning and operating plates on the Keating MIRACLEAN ® Griddle should be in place at all times. If plates are damaged or lost, replace them immediately.
  • Page 15: Wiring Diagram

    GAS GRIDDLE WIRING DIAGRAM CONTROL PANEL THERMOSTAT ON/OFF SWITCH...
  • Page 17: Service Information

    DATE OF PURCHASE: ________________________________________________________________ INVOICE NUMBER: ____________________ SERIAL NUMBER: ________________________________________ REMARKS: ______________________________________________ I HAVE READ THE INSTALLATION AND OPERATION INSTRUCTIONS. SIGNED: ____________________________________________________________________________________ DATE: __________________________ SERVICE INFORMATION KEATING OF CHICAGO, INC. www.keatingofchicago.com KEATING LIMITED WARRANTY CARD FRYER TOP-SIDE COOKER ® “Serving Those Who Serve The Very Best ”...