Keating Of Chicago 2000 Installation Manual

Gas griddle
Hide thumbs Also See for 2000:

Advertisement

Quick Links

INSTALLATION MANUAL
USER OPERATION and MAINTENANCE
READ AND SAVE THIS MANUAL FOR FUTURE REFERENCE
Record the Model No. and Serial No. of this Miraclean® Griddle in the space provided below.
Serial No.
Model No.
Keep these numbers for future reference.
IMPORTANT: Keep a copy of your bill of sale. The date on the bill establishes the warranty period should
service be required. If service is performed, it is in your best interest to obtain and keep all receipts.
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Installation Instructions . . . . . . . . . . . . . . . . . . . .1
Damage in Shipment . . . . . . . . . . . . . . . . . . . . . . .1
Positioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
National Code Requirements . . . . . . . . . . . . . . . .1
Gas Connections and Pipe Size . . . . . . . . . . . . . .2
Flexible Gas Connections & Quick
Disconnect Devices . . . . . . . . . . . . . . . . . . . . .2
Leveling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Lighting Instructions . . . . . . . . . . . . . . . . . . . . . . .3
This Owner's Guide provides specific operating instructions for your model.
Si desea obtener una copia en español de este Manual del Usuario,
*As continuous product improvement occurs, specifications may be changed without notice.
GasGrid 2000
9/05
037399
"Serving Those Who Serve The Very Best"
MIRACLEAN
GAS GRIDDLE
SERVICE INSTRUCIONS
CONTENTS
Versión en español
sírvase escribir la dirección que se incluye a continuadión.
1-800-KEATING
®
2000
®
Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Cooking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4
Preventative Maintenance . . . . . . . . . . . . . . . . . . .5
Avoid Service Checklist . . . . . . . . . . . . . . . . . . . .5
Cleaning Care & Conditioning . . . . . . . . . . . . . .5,6
Thermostat Calibration . . . . . . . . . . . . . . . . . . . . .6
Service Parts Ordering . . . . . . . . . . . . . . . . . . . .6-7
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . .11

Advertisement

Table of Contents
loading

Summary of Contents for Keating Of Chicago 2000

  • Page 1: Table Of Contents

    Si desea obtener una copia en español de este Manual del Usuario, sírvase escribir la dirección que se incluye a continuadión. *As continuous product improvement occurs, specifications may be changed without notice. GasGrid 2000 9/05 037399 “Serving Those Who Serve The Very Best”...
  • Page 2 be followed in the event the user smells gas. This information shall be obtained by consulting the local gas supplier. Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
  • Page 3: Introduction

    INTRODUCTION Instructions in this manual should be read thoroughly before attempting to operate this Miraclean® Griddle. All installation and service on Keating equipment must be performed by qualified, certified, licensed and/or authorized installation or service personnel. Service information for Keating equipment has been prepared for use by qualified and/or authorized personnel.
  • Page 4: Gas Connections And Pipe Size

    GAS CONNECTIONS AND PIPE SIZE The Miraclean® Griddle requires a standard gas pipe size of 3/4 inch (19mm) I.D. connection. The size of the gas supply pipe is very important if the pipe is too small you will have low gas pressure at the Miraclean® Griddle manifold.
  • Page 5: Lighting Instructions

    PLACING MIRACLEAN® GRIDDLE IN OPERATION (When all previous instructions have been completed). Check the serial plate to determine if the burner is set up for the proper type gas before connecting the quick- disconnect or piping from the building gas supply pipe. a.
  • Page 6: Cooking

    becomes thicker. It becomes more of a meat cake than a hamburger. Therefore, the hamburger spatula has a strong cutting edge. is shown in this illustration. An egg spatula has a long very thin blade so that it can be slipped under the egg without damaging it or breaking the yolk.
  • Page 7: Preventative Maintenance

    WARRANTY REPAIRS Keating’s warranty begins with the date of installation. In the event that your Miraclean® Griddle, under warranty, needs repairs other than routine cleaning, you are requested to contact KEATING OF CHICAGO, INC. (1-800 KEATING). CLEANING THE MIRACLEAN® GRIDDLE The surface of the MIRACLEAN®...
  • Page 8: Thermostat Calibration

    CLEANING CABINET The front, back and sides of the cabinet should be kept clean for sanitary reasons. CARE OF THE MIRACLEAN® SURFACE The Miraclean® surface is very hard. With proper care, the MIRACLEAN® surface and its unique cooking properties will last for many years. NEVER USE A GRIDDLE STONE, BRICK OR SCREEN CLEAN...
  • Page 9: Parts List

    Figure 6-2 Figure 6-3 Natural and Propane Gas Heating Systems ITEM DESCRIPTION SPARK IGNITION ASSEMBLY SEE Item 4, Figure 6-2 THERMOPILE PILOT TUBE (1/4”) PILOT ASSEMBLY (ALL NATURAL GAS, 24”-30” LP, 24”-39” BEF) NATURAL GAS ORIFICE PROPANE ORIFICE BURNER INSERT BURNER AIR SHUTTERS MAIN SUPPLY GAS VALVE 3/4"...
  • Page 10: Thermostat Removal & Replacement

    GAS VALVE REGULATOR ADJUSTMENT Recommended gas pressure at manifold (4.0" W.C. Natural gas 10.0" W.C. Propane gas) Adjustment of the gas valve pressure regulator is not normally necessary since it has been preset at the factory. During installation, the gas pressure should be checked at each gas valve with all burners operating.
  • Page 11 THERMOSTAT BULB PLACEMENT DETAIL MILLIVOLT CHECK (FOR QUALIFIED SERVICE TECHNICIANS ONLY) The millivolt valve is a thermopile self-powered combination gas control. Before checking the millivolt system, the following operations should be performed and observations made: 1. A genuine Keating millivolt thermostat should be used for millivolt operation. 2.
  • Page 12: Service Diagnosis/Trouble Shoot Chart

    B. THERMOPILE OUTPUT CHECK (“B” Reading. Thermostat contacts OPEN - Main burner OFF.) 1. Thermopile system - 325 millivolts minimum. If the minimum millivolt reading is not obtainable, readjust thermopile for maximum millivolt output. If millivolt reading is still below minimum specified, replace thermopile. C.
  • Page 13: Wiring Diagram

    Pilot on but no main a. ON/OFF switch is in “OFF” burner ignition position. b. Gas valve is in “pilot” position. c. Thermostat is not turned on. d. Low gas pressure. e. Gas valve failure. Temperature of a. Thermostat is not calibrated. griddle erratic b.
  • Page 15 Please state the nature of the call; it will ensure speaking with the appropriate person. Have your serial and model number available when ordering parts. KEATING OF CHICAGO, INC. Phone: (708) 544-6500 FAX: (708) 544-6505 Toll Free 1-800-KEATING (In U.S. and Canada) www.keatingofchicago.com...

Table of Contents