Adamson M Series User Manual page 18

Table of Contents

Advertisement

General - General system parameters
SYSTEM-SETUP MENU:Sampling
SAMPLING RATE:96kHz
• FREQ MODE - Selects the frequency control mode for EQ and crossover filters. Can be 6 steps/octave or All
Frequencies ( Hz resolution).
• DELAY UNIT - ms, ft or m.
• DEVICE# - Assigns the device ID from  to 6. This ID is useful when a network of more than  unit is present.
PC Link - PC Link Enable
SYSTEM-SETUP MENU:General
FREQ MODE :All Freq
DELAY UNIT:01
DEVICE# :1
• PCLINK: - PC Link Enable. It enables (On) or disables (Off) RS22 communication with the PC software. It is
recommended to turn off the link when the unit is not connected to the PC.
Sampling - Sampling Rate Selection
SYSTEM-SETUP MENU:PC Link
PCLINK:On
• SAMPLING RATE: - Sampling Rate selection. The unit can operate under 48kHz or 96kHz sampling rate
according to this option. The device has to be shut down and turned back on for the hardware effect to take
place. For 96kHz operation, crossover slopes can be up to 24dB/Oct only, while 48kHz gives crossover slopes to
48dB/Oct.