Verifying Proper Operation
WARNING
Make sure that power t0 the electrical outlet is turned
off at the circuit breaker or fuse box and that the gas is
turned off at the gas supply valve before proceeding.
,
The cooktop must be properly grounded at all times
when electrical power is applied: ...............
Prior to operating the cooktop, read the accompanying
use
and care manual carefully.
1.
Make sure all the cooktop burner controls are in the
OFF position.
2.
Connect the power cord to the electrical outlet.
3.
Turn on power to the electrical outlet at the circuit
breaker or fuse box.
,
,
6.
Gently push in and turn one burner control knob at a
time counterclockwise
to the HIGH position. Verify that
burner igniters spark, then return the knob to the OFF
position. Repeat for all of the remaining control knobs.
Turn on the gas supply valve.
Perform the following ignition test for all of the burners:
• Push in and turn one of the control knobs counter-
clockwise to the HIGH position. The igniters for all
the burners will spark. It may take up to four seconds
for the gas from the selected burner to ignite, at
which time the igniters will stop sparking. If ignition
does not occur within four seconds, turn the knob
to the OFF position, wait for at least five minutes to
allow any gas to dissipate, then repeat the test.
• Once the burner lights, the control knob can be rotat-
ed counterclockwise
from HIGH to LOW to adjust the
flame height progressively.
When the unit is installed properly, the flame will be
steady. It will also have a sharp, blue inner cone that
will vary in length proportional to the burner size. The
flame will be reduced by the Smart Flame
TM
feature
under the grate fingers to increase grate life.
NOTE: If the cooktop
does not operate properly, follow
these troubleshooting
steps:
Verify that power and gas are supplied to the cooktop.
Check to make sure that the power plug is connected
to the electrical outlet and that power is turned on at
the circuit breaker or fuse box.
Check to make sure that all burner parts are properly
seated.
If the burner continues to spark after ignition without
stopping, have a licensed electrician check the electri-
cal outlet for proper grounding or reversed polarity.
Repeat the above burner ignition test.
If the appliance still does not work, contact Dacor
Distinctive Service at (877) 337-3226. Do not attempt to
repair the appliance yourself. Be sure to have the model
and serial numbers available when you call. See the inside
cover for location.
Dacor is not responsible for the cost of correcting problems
caused by a faulty installation.
OFF position
/
LIGHT and HIGH
t
position
o
LOW position
Burner Control
Burner indicator
Knob
light
Normal Flame
Appearance
10 c_acar