Available languages

Four Conductor
Wire Connection
to Range
(mobile
homes)
1. Remove the 3 screws at the lower end of the rear
wire cover, then raise the lower end of the rear wire
cover (access cover) upward to expose range
terminal connection
block (see figure 3).
2. Remove the 3 loose nuts (after you remove the
rubber band) on the terminal block using a 3/8"(0,95
cm) nut driver or socket.
3. Remove the ground strap from the terminal block
and from the appliance frame.
4. Connect the ground wire (green) of the copper
power supply cord to the frame of the appliance
with the ground screw, using the hole in the frame
where the ground strap was removed (see Figure 5).
5. Connect the neutral of the copper power supply cord
to the center silver-colored terminal of the terminal
block, and connect the other wires to the outer
terminals. Match wires and terminals by color (red
wires connected to the right terminal, black wires
connected to the left terminal).
6. Replace the 3 nuts on the terminal block (see figure
5).
7. Lower the terminal cover and replace the 3 screws.
Terminal
Block
Silver Colored
Terminal
Red
Wire
Direct
Electrical
Connection
to the Circuit
Breaker,
Fuse Box or Junction
Box
If the appliance is connected directly to the circuit
breaker, fuse box or junction box, use flexible, armored
or nonmetallic sheathed copper cable (with grounding
wire). Supply a U.L listed strain-relief at each end of the
cable. At the appliance end, the cable goes through the
Direct Connection
Hole (see Figure 5) on the Cord
Mounting
Plate. Wire sizes (copper
wire only) and
connections must conform to the rating of the appliance.
Where
local
codes
permit
connecting
the appliance-
grounding
conductor
to the neutral
(white)
wire
(see Figure
6):
1. Disconnect
the power
supply.
2. In the circuit breaker,
fuse box or junction
box:
a) Connect
the green (or bare copper)
wire, the
white
appliance
cable wire, and the neutral
(white)
wire together.
b) Connect
the 2 black wires together.
c) Connect
the 2 red wires together.
Cable from
Residence
Neutral
(white) Wire
Red
Wires
Black Wire
1 1/8" (2.9 cm)_/
Dia. Direct
w
Connection
Hole.
Punch
Out Knockout
for 1 3/8 (3.5
cm) Dia. Cord
Kit
Hole.
A User SupF
Strain-relief
Must
Be Installed
at
This Location
To 240 V Receptacle
NOTE:
Be sure to remove
the
supplied
grounding
strap.
Box
Wire
Green
Conduit
(or Bare Copper)
Connector
(or CSA
Wire
Cable from
listed)
Appliance
Figure
6
3-Wire
(Grounded
Neutral)
Electrical
System
(Example:
Junction
Box)