United States
INSTALLATION AND SERVICEMUST BE PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT:
SAVE FOR LOCAL ELECTRICAL INSPECTOR'S
USE.
READ AND SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE.
FOR YOUR SAFETY: Do not store or use gasoline or other
flammable
vapors and liquids in the vicinity of this or any other appliance.
(7cm
Min,) for
Open door.
only, if there is a
40 1/8" Min.
(101.9cm)
30" Min.**
(76.2cm Min.)
18" Min.
'13"
Max.
(45.7cm Min.) (33cm Max.)
36 318"÷
............
(92.4cm)
B .............
_1
(91.4cm)
A
Grounded
24" Min.
Wall Outlet
(61cm Min.)
24Y2" max.
(62.2cm Max.)
Do not pinch the power supply cord between the range
and the wall.
Do not seal the range to the side cabinets.
D
**NOTE: 24" (61 cm) minimum clearance between
the cooktop and the bottom of the cabinet when the
bottom of wood or metal cabinet is protected by not less
than 1/4" (0.64 cm) flame retardant millboard covered
with not less than No. 28 MSG sheet metal, 0.01 5"
(0.4 ram) stainless steel, 0.024" (0.6 mm) aluminum, or
0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance when the cabinet is
unprotected.
48 1/8"
(122.2cm)
40 1/8"
26 1/4" (66.7cm)
44 5/8 (113.3cm)
40 1/4" (102.2cm)
(101.9cm)
with Handle28 1/2" (72.4cm)
36" (91.4cm) standard
35 7/8" (91.1cm) rain.
P/N 318201704 (0907) Rev.B
English - pages 1 - 8
Espaflol - p_iginas 9 - 16

Advertisement

loading

Summary of Contents for Frigidaire FPEF4085KFC

  • Page 1 INSTALLATION AND SERVICEMUST BE PERFORMED BY A QUALIFIED INSTALLER. United States IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. 40 1/8"...
  • Page 2 Before installing the range in an area covered important Notes to the Installer Read all instructions contained in these installation with linoleum or any other synthetic floor covering, make sure the floor covering instructions before installing range. withstand heat at least 90°F/32°C above room Remove all packing material from the oven temperature without...
  • Page 3: Power Supply Cord Kit

    2. Access to Terminal Block & Model Serial Number Location The serial plate is located on the oven front frame behind Grounding Strap the large oven door. When ordering parts for or making inquiries about your range, always be sure to include the model and serial numbers and a lot number or letter from the serial plate on your range (Figure 1).
  • Page 4 Four Conductor Wire Connection Range 3, Electrical Connection to the Range Where local codes does NOT permit connection of the frame grounding conductor to the neutral wire of the Three Conductor Wire Connection Range copper power supply cord (see Figure 4): If local codes permit connection of the frame grounding 1.
  • Page 5 Direct Electrical Connection to the Circuit Where local codes DO NOT permit connecting appliance-grounding conductor to the neutral Breaker, Fuse Box or Junction (white) wire, or if connecting to 4-wire electrical If the appliance is connected directly to the circuit system (see Figure 6): breaker, fuse box or junction box, use flexible, armored Be sure that no power is supplied on the cable from...
  • Page 6 Junction Location on the floor where the back edge of the range will be. Now install anti-tip brackets (see "Anti-Tip Brackets Locate junction box as shown in Figure 7. Installation" page 8). If a service cord is used, the wall receptacle should be located in accordance with the dimensions below.
  • Page 7 Bake-After setting the oven to 350°F (177°C) for Leveling Range baking, the lower element in the oven should become Level the range and set cooktop height before red. installation in the cut=out opening (if applicable). Install an oven rack in the center of the oven. Broil-When the oven is set to BROIL, the upper element Place a level on the rack (see figure 9).
  • Page 8 Unfold paper template and place it flat on the floor important Safety Warning with the back and side edges positioned exactly To reduce the risk of tipping of the range, the range where the back and sides of range will be located must be secured to the floor by properly installed anti-tip when installed.
  • Page 9 LA INSTALACION Y EL SERVICIO DEBEN SER EFECTUADOS POR UN Estados Unidos iNSTALADOR CAUFICADO. iMPORTANTE: GUARDE ESTAS iNSTRUCCIONES PARA USO DEL iNSPECTOR LOCAL DE ELECTRICIDAD. LEA Y GUARDE ESTAS iNSTRUCCIONES PARA REFERENCIA FUTURA. PAPA SU SEGURIDAD: No aimacene ni utilice gasoiina u otros vapores y Iiquidos inflamabies en la proximidad de este o de cuaiquier otto artefacto.
  • Page 10 • Antes de instalar la estufa en un _rea cuyo piso Notas importantes para el Instalador este recubierto con lin61eo u otto tipo de piso Lea todas las instrucciones contenidas en este manual antes de instalar la estufa. sintetico, asegurese de que estos puedan resistir una temperatura...
  • Page 11 Ubicacion del Numero de Modelo y de Serie 2. Acceso a la terminal del bloque La placa con el n0mero de serie est,1ubicada en el marco la correa de tierra delantero del homo detr_is de la puerta del homo grande. Cuando haga pedidos de repuestos o solicite informacion con respecto a su estufa, este siempre seguro de incluir el n0mero de modelo y de serie y el n0mero o letra del Iote de...
  • Page 12 Conexi6n del cable de cuatro conductores Conexion electrica a la cocina ia cocina. Conexi6n del cable a tres alambres ia cocina 1. Retire los 3 tornillos de la parte baja de la cubierta Si los c6digos locales permiten la conexi6n del conductor a del cable trasero, luego levante la cubierta hacia tierra del armaz6n al alambre neutral del cable de bronce arriba para tener acceso (cubierta de acceso) al...
  • Page 13 Conexion electrica directa ai cortacircuito, Donde los c6digos locales NO permitan conectar el conductor de puesta a tierra del electrodom_stico ia caja de fusibles o ia caja de empalmes neutral (blanco), o si est_ conectado con un sistema a Si el aparato est_S conectado directamente al cortacircuito, 4 alambres (vea figura 6): a la caja de fusibles o a la caja de empalmes, use un cable Desconecte el suministro el_ctrico.
  • Page 14 parte trasera de la estufa no estar_ a ras con la pared Situad6n de caja de uni6n (la ubicacion del tomacorriente puede que no permita que la Localice la caja de empalmes como se ve en la Figura 7. estufa se pegue a ras con la pared), marque el piso donde el Si se usa un cord6n de servicio, el recept_iculo de pared borde trasero de la estufa estate1.
  • Page 15 Nivelad6n de ia estufa Convecd6n/Convection-Cuando el homo se pone a CONV. BAKE/ROAST a 350°F (177°C), los dos elementos Nivele la estufa y ajuste la altura de la estufa antes enciendan y se apagan alternando en un ciclo y el ventilador insta[arla en la abertura, se pone en marcha.
  • Page 16 Importante Advertencia de Seguridad Desdoble la plantilla de papel y col0quela plana en el piso con los bordes laterales y el trasero colocados Para reducir el riesgo de que la estufa se vuelque, es exactamente donde la parte trasera y los lados de la necesario asegurarla al piso instalando los soportes estufa set,in colocados cuando sea instalada.