INSTALLATION
AND SERVICE
MUST BE PERFORMED
BYA QUALIFIED
INSTALLER.
IMPORTANT:
SAVE FOR LOCAL
ELECTRICAL
INSPECTOR'S
USE.
READ AND SAVE THESE INSTRUCTIONS
FOR FUTURE
REFERENCE.
Clearances
and Dimensions
1.
Provide adequate clearances between the range and adjacent combustible surfaces.
2.
Location--Check
location where the range will be installed. Check for proper electrical supply, and the stability
of the floor.
3.
Dimensions that are shown must be used. Given dimensions provide minimum clearance. Contact surface must
be solid and level.
..................
Minimum to
wall on either
1"$
to
side of range
above 36" height.
iiiiiiii
i
_® _
®®]18
eitherside
I
/
i_
of range.
_
30" _
SIDE
VIEW
I_13"_'1
Maximum
depth
r-
for cabinets
[F
above range top.
O' clearance below cooking l_p and at rear of range.
RANGE
OVERALL
DIMENSIONS
253/4 '
445/8"
Door Open
,,_"_
\
29 7/8
_ _ _
Centerline
of range
2-5/8" for models equipped
with warmer drawers"
3-1/2" for models equipped
with storage drawers
Wall
Edge
*30" MINIMUM
CLEARANCE
BETWEEN
THE TOP OF THE COOKING
SURFACE
AND THE
BOTTOM
OF AN
UNPROTECTED
WOOD OR METAL CABINET; OR 24" MINIMUM WHEN BOTTOM OF WOOD OR METAL CABINET IS
PROTECTED
BY NOT LESS THAN 1/4" FLAME RETARDANT
MiLLBOARD COVERED WITH NOT LESS THAN NO. 28
MSG SHEET STEEL, 0.015" STAINLESS
STEEL, 0.024" ALUMINUM
OR 0.020" COPPER.
0" CLEARANCE
IS THE
MINIMUM FOR THE REAR OF THE RANGE. FOLLOW ALL DIMENSION
REQUIREMENTS
PROVIDED ABOVE TO
PREVENT PROPERTY DAMAGE, POTENTIAL FIRE HAZARD, AND INCORRECT COUNTERTOP AND CABINET CUTS.
TO ELIMINATE THE RISK OF BURNS OR FIRE BY REACHING OVER HEATED SURFACE UNITS, CABINET STORAGE
SPACE
LOCATED
ABOVE THE SURFACE
UNITS SHOULD
BE AVOIDED.
IF CABINET
STORAGE
IS TO BE
PROVIDED, THE RISK CAN BE REDUCED BY INSTALLING A RANGE HOOD THAT PROJECTS HORIZONTALLY
A
MINIMUM OF 5" BEYOND THE BOTTOM OF THE CABINETS.
PIN 316259200 REV B (0211)
1
EspaSol - P_ginas 5-8