Where local codes DO NOT permit connecting the
appliance-grounding
conductor to the neutral
(white)
wire, or if connecting to 4-wire electrical
system (see Figure 7):
1.
Disconnect the power supply.
2.
Separate the green (or bare copper) and white
appliance cable wires.
3.
In the circuit breaker, fuse box or junction box:
a) Connect the white appliance cable wire to the
neutral (white) wire.
b) Connect the 2 black wires together.
c) Connect the 2 red wires together.
d) Connect the green (or bare copper) grounding
wire to the grounding wire of the circuit breaker,
fuse box or junction box.
Cable from
Residence
Green (or Bare
Copper) Wire
White
Wire
Green (or Bare
Copper)
Wire
White
Wire
Junction
U.L-listed
Conduit
Box
Connector
(or CSA
Cable from
listed)
Appliance
Figure 7 - 4-Wire
Electrical System
(Example: Junction Box)
Cabinet
Construction
To eliminate the risk of burns or fire by
reaching over heated surface units, do not have cabinet
storage space above the range. If there is cabinet
storage space above range, reduce risk by installing a
range hood that projects horizontally a minimum of 5"
(12.7 cm) beyond the bottom of the cabinet.
Countertop
Preparation
• The cooktop sides of the range fit over the cutout edge
of your countertop.
• If you have a square finish (flat) countertop,
no
countertop preparation is required.
• Formed front-edged
countertops
must have molded
edge shaved flat 3/4" (1.9 cm) from each front corner
of opening.
• Tile countertops
may need trim cut back 3/4"(1.9cm)
from each front corner and/or rounded edge flattened.
Min.
cutout
A..--'"widt h
(1 =9 icm)
3/4"
(1.9 cm)
/-
31 1/2 'r"
(81 cm)
Formed or tiled countertop
trimmed
3/4" (I ,9cm)
back at front corners of
countertop
opening.
Figure 8
• If the countertop
opening
width
is greater
than
the minimum
cutout
width,
adjust the 3/4"
(1.9
cm) dimension.
For countertop
of 29" (73.7cm)
cutout
wide
onenino:
You mustamso
r-
-
=l
clear
2 3/16"
(5.56
cm)
of
2 3/16"
material from front to back
2 3/16"
B cm)
of countertop
and 30" wide
5 cm)
in matter
tofit
the
range
in the cabinet.
1 1/4"
(3.2
cm)
Formed
or tiled
countertop
trimmed
1 1/4" (3.2cm)
(3=2 icm)
back
at front
corners
of
countertop
opening
for 29"
cutout
wide opening.
• Countertop
must
be level.
Place a level on the
countertop,
first side to side, then front to back. If the
countertop
is not level, the range will not be level. The
oven must be level for satisfactory
baking
results.
Cooktop
sides of range fit over edges of countertop
opening
6

Hide quick links: