Frigidaire FMV145KB2 Installation Instructions Manual page 5

Over the range microwave oven
Table of Contents

Advertisement

Installation
Instructions
NOTE:
If you need to install ducts, note that the total
duct length of 3 V/' x 10" rectangular
or 6" diameter
round
duct should not exceed 140 equivalent
feet (42.67 m).
Outside ventilation
requires
a HOOD EXHAUST
DU(T.
Read the follo_dng carefiflly.
NOTE:
It is important
that venting be installed
using
the most direct route and with as tew elbows as possible.
This ensures cleat venting of exhaust and helps prevent
blockages.
Also, make sure dampers
swing freely and
nothing
is blocking the ducts.
Exhaust connection:
The hood exhaust
has been designed
to mate with a
standard
3V/' x 10" rectangular
duct.
If a round duct is required,
a rectangular-to-round
transition
adaptor
must be used. Do not use less than
a 6" diameter
duct.
Maximum
duct length:
For satisLt{ to D air movement,
the total du{t length of
3]/, " x 10" rectangular
or 6" diameter
round duct should
not exceed 140 equivalent
feet (42.67 m).
Elbows, transitions,
wall and roof caps,
etc.,
present additional
resistance
to airflow and are
equiwtlent
to a section of straight duct which is longer
than their actual physical size. When calculating
the
total duct length, add the equivalent
lengths of all
transitions
and adaptors
plus the length of all straight
duct sections. The chart below shows you how to
calculate
total equivalent
duclwork length using the
approximate
teet of equivalent
length of some typical
ducts.
EQUIVALENT
NUMBER
EQUIVALENT
DUCT PIECES
LENGTH
x
USED
=
LENGTH
Rectangular-to-Round
5 Ft.
x
(
}
=
Ft.
TransitionAdaptor*
(1,52m)
(m)
Wall Cap
40 Ft.
x
(
)
=
Ft.
(12.19m)
(m)
()_
go °Elbow
10 Ft.
x
(
)
=
Ft.
(3,05m)
(m)
{_
45° Elbow
5 Ft,
x
(
)
=
Ft.
(1,52m)
(m)
go ° Elbow
25 Ft.
x
(
)
=
Ft.
(7,62m)
{m)
45° Elbow
5 Ft.
Ft.
( )
X
(1£2 m}
(m)
Roof
24 Ft.
(
}
Ft.
Cap
×
(7,32m}
(m)
StraightDuct6" Roundor
1 Ft.
x
(
)
=
Ft.
374"x 10" Rectangular
(30,48cm}
(cm)
Total Ductwork
=
Ft. {m}
* IMPORTANT:
lla I('LlalI_ulaI-I(}-F(}uI3d
tlansiti(}n
E( uivalent
1€nNhs
of dtlcl
Die (:€s arc bas((l
()ll a(:tua[
tcsIs
adaplor
is used, th( botlom Comers of the dam )(r
and r_ flecI te( uirements
lbr good vc n/ing peHbnnance
with
willhaveIobe cut to
ill, using
the tinsnips,in
or(let
al]x
vent hood.
to all{*_ free naoxement o f tla_
damper.
5