Ventilation System - Frigidaire FGMV174KFA Installation Instructions Manual

Over the range
Hide thumbs Also See for FGMV174KFA:
Table of Contents

Advertisement

Available languages

Available languages

8
VENTiLATiON SYSTEM
(PREPARiHG 8VEH FOR IHSTALLATIOH)
This microwave oven/hood is designed for adaptation to three
types of hood ventilation systems. Select the type required
for your installation.
RECIRCULATING -- non-vented, ductless.
Follow installation procedure (A). Recirculating
requires
the use of the Charcoal Filter, which has already been
installed in the oven.
HORIZONTALEXHAUST-- outside ventilation.
Follow installation procedure (B).
VERTICALEXHAUST-- outside ventilation.
Follow installation procedure (C).
(A)
I.
2.
3.
BECIBCULATING:
NON-VENTED, D UCTLESSOPERATION
The unit is shipped assembled for recirculating.
The
Exhaust
Damper
Assembly
is not required
for
recirculating exhaust.
Charcoal Filter, which was installed in your microwave
oven, is used for nonvented, recirculated installation. The
Charcoal Filter should be replaced every 6 to 12 months,
depending on use. Remove three Hood Louver screws.
Tilt the Hood louver downward then pull it out so bottom
tabs become unlocked. Pull the Charcoal Filter upward
to remove from your oven. Attach the Charcoal Filter to
the upper side of the oven by sliding into the tabs. See
Figure 6-1,6-2.
Charcoal filter
Oven light
(B)HOBIZONTAL EXHAUST: O UTSIDE
VENTILATION
1. Remove and save 2 screws from back edge and 1 screw
from the top center of Fan Cover Bracket. Remove Fan
Cover Bracket by sliding it in the opposite direction of the
arrow on the Fan Cover Bracket, as shown in Figure 7.
2. Withdraw Hood Fan Unit carefully and slip wires out of
Wire Box. See Figure 8.
CAUTION:Do not pull or stretch hoodfan wiring.
3. Rotate the Hood Fan Unit and turn end-over-end
so that
the fan blade openings are facing the back of the oven.
Replace Hood Fan Unit into the oven. Be careful not to
pinch the lead wire between the inner bracket and the
Hood Fan Unit. See Figure 9.
4. Put the lead wire into Wire Box. See Figure 10.
5. Replace the Fan Cover Bracket by sliding it into the slits
in the same direction as the arrow on the Fan Cover
Bracket. Make sure the fan blades are visible through the
rear openings in the oven before proceeding. Attach Fan
Cover Bracket to unit with 3 screws, which were removed
in Step 1 above. See Figure 11. The Hood Fan Unit is
now rotated for horizontal exhaust operation.
6. Attach the Exhaust Damper Assembly to the back of the
unit. See Figure 10. Use two Tapping Screws 4 x 8 mm from
the INSTALLATION HARDWARE and tighten into place.
Fan Cover Bracket
/
\\
Backer
/
Oven
Figure 7
Bottom tab
Tabs
Tabs