Download Print this page

Ventilation Methods Hot Air Exhaust; Power Level P-0 To P-90 Cooking; Power Output Reduction - Frigidaire CGMV173KB Servicing

Hide thumbs

Advertisement

VENTILATION METHODS HOT AIR EXHAUST

1. Vertical Venting
For this venting method, hot air rising from the
conventional range below is drawn in by the hood fan
motor through the grease fi lters at the right and left
sides of the base cover, up through the right and left
sides of the oven cavity, then discharged vertically at rear
center top of the oven, into the customer's vent system.
Air Flow
To Duct
2. Horizontal Venting
The air handing is the same as Vertical Venting except
that fi nal air discharge is directed horizontally out from
the top rear of oven into the customer's vent system.
Air Flow
Hood Fan Motor
3. Re-circulation (Inside venting)
The air handing is the same as VERTICAL VENTING
except that the final air discharge is directed horizontally
through the upper front of the oven into the kitchen.
Air Flow
Hood Fan Motor
To Duct
Hood Fan Motor
Hood
Intake
Duct
Grease
Filter
To Duct
Hood
Intake
Duct
Grease
Filter
Hood Exhaust
Charcoal
Louver
Filter
Hood
Intake
Duct
Section 2 Operation

POWER LEVEL P-0 TO P-90 COOKING

When Variable Cooking Power is programmed, the
120 volts A.C. is supplied to the power transformer
intermittently through the contacts of relay (RY2) which
is operated by the control unit within an interval second
time base. Microwave power operation is as follows:
Vari-Mode
Power 10 (High) (100% Power) 32 sec.
Power 9 (P-90) (Approx. 90%)
Power 8 (P-80) (Approx. 80%)
Power 7 (P-70) (Approx. 70%)
Power 6 (P-60) (Approx. 60%)
Power 5 (P-50) (Approx. 50%)
Power 4 (P-40) (Approx. 40%)
Power 3 (P-30) (Approx. 30%)
Power 2 (P-20) (Approx. 20%)
Power 1 (P-10) (Approx. 10%)
Power 0 (P-0) (0% power)
NOTE
The ON/OFF time ratio does not correspond with
the percentage of microwave power, because
approximately 2 seconds are needed for heating of
the magnetron filament.

POWER OUTPUT REDUCTION

If the oven is set for over 40 minutes at 80%, 90% or
100% power level, after the first 40 minutes the power
level will automatically adjust itself to 70% power to
avoid overcooking.
ON TIME
OFF TIME
0 sec.
30 sec.
2 sec.
26 sec.
6 sec.
24 sec.
8 sec.
22 sec.
10 sec.
18 sec.
14 sec.
16 sec.
16 sec.
12 sec.
20 sec.
8 sec.
24 sec.
6 sec.
26 sec.
0 sec.
32 sec.
2-3

Advertisement

loading

This manual is also suitable for: