Step 8, Connect Electrical - GE Monogram ZET1058 Installation Instructions Manual

30" convection built-in ovens
Hide thumbs Also See for Monogram ZET1058:
Table of Contents

Advertisement

Installation
Instructions
[STEP
CONNECT
ELECTRICAL
WARNING
ELECTRICAL
SHOCK
HAZARD
• Electrical ground is required on
this appliance
• DO NOT connect to the electrical
supply until appliance is perma-
nently grounded.
• Disconnect power to the junction box before
making the electrical connection.
• This appliance must be connected to a grounded,
metallic, permanent wiring system or a grounding
connector should be connected to the grounding
terminal or wire lead on the appliance.
Failure to do so could result in fire, personal injury or
electrical shock
AVERTISSEMENT
RISQUE
DE CHOC
I_LECTRIQUE
• Cet appareit dolt _tre mis _ la
terre.
• NE PAS brancher l'alimentation
_lectrique si l'appareil n'est pas
mis _ la terre de fa_on permanente.
• D_brancher I'alimentation au boftier de
raccordement
avant de faire le branchement
_lectrique.
• Cet appareil doit _tre branch_ sur un circuit perma-
nent m_tattique _ la terre ou un connecteur de mise
laterre
doit _tre branch_ Q la borne de mise _ la
terre ou un fil de l'appareil
I1faut suivre ces instructions pour _viter des
incendies, des blessures graves ou la mort.
3-Conductor Branch Circuit
Branch Circuit
Red
120V AC
White or
Neutral
Gray
120V AC
Black
Oven
Red
Green
I White
Black
When
connecting
to a 3-conductor
branch
circuit:
• Connect oven red lead to branch circuit red lead.
• Connect oven black lead to branch circuit black
lead
• Connect oven bare copper conductor and white lead
to branch circuit neutral lead (white or gray)
4-Conductor Branch Circuit
Branch Circuit
Oven
Red
Red
120VAC
120VAC
Black
Black
Green
White
GND
Neutral
Bare or
Green
White or
Gray
When
connecting
to a 4-conductor
branch
circuit:
• Connect oven red lead to branch circuit red lead.
• Connect oven black lead to branch circuit black
lead
• Break connection between oven white lead and
oven bare copper conductor.
• Connect oven white lead to branch circuit neutral
lead (white or gray).
• Connect oven bare copper conductor to branch
circuit ground lead (green or bare copper).
Note: Use copper wire only.
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Monogram zet1038

Table of Contents