EXHAUST INFORMATION
WARNING
-IN
CANADA
AND IN
THE UNITED
STATES, THE REQUIRED
EX-
HAUST DUCT DIAMETER
IS 4 IN (102ram).
DO
NOT USE DUCT LONGER THAN SPECIFIED IN
THE EXHAUST LENGTH TABLE.
Using exhaust longer than specified length will:
, Increase the drying times and the energy cost.
, Reduce the dryer life.
, Accumulate lint, creating a potential fire hazard.
The correct exhaust installation
is YOUR
RESPONSIBILITY. P roblems due to incorrect
installation
(]re not covered by the warranty.
Remove and discard existing plastic or metal foil
transition duct and replace with UL listed transition
duct.
The MAXIMUM ALLOWABLEduct length and number
of bends of the exhaust system depends upon the
type of duct, number of turns, the type of exhaust
hood (wall cap), and all conditions noted below. The
maximum duct length for rigid metal duct is shown in
the table below.
27" DRYER EXHAUST LENGTH
RECOMMENDED M AXIMUMLENGTH
Exhaust Hood Tgpes
Recommended
Use onlg for short
run installations
4" DIA
No, of 90 °
Rigid
Rigid
Elbows
Metal
Metal
0
56 Feet
42 Feet
1
46 Feet
36 Feet
2
34 Feet
28 Feet
3
32 Feet
18 Feet
24" DRYER EXHAUST LENGTH
RECOMMENDED M AXIMUMLENGTH
Exhaust Hood Tgpes
Use onlg for short
run installations
4" DJA
2 1/2"
Recommended
Rigid.
Metal
/43 Feet
33 Feet
2/4 Feet
No, of 90°
Rigid
Elbows
Metal
0
36 Feet
1
26 Feet
2
26 Feet
EXHAUST INFORMATION
(cant}
EXHAUST SYSTEM CHECK LIST
HOOD OR WALL CAP
. Terminate in a manner to prevent back drafts or entry
of birds or other wildlife.
, Termination should present minimal resistance to
the exhaust air flow and should require little or no
maintenance to prevent clogging.
,Never install a screen in or over the exhaust duct. This
could cause lint build up.
, Wall caps must be installed at least 12 in. above ground
level or any other obstruction with the opening pointed
down.
SEPARATIONOF TURNS
For best performance, separate all turns by at least 4 ft.
of straight duct, including distance between last turn and
exhaust hood.
TURNS OTHERTHAN 90 °
, One turn of 450 or less may be ignored.
, Two 450 turns should be treated as one 900 turn.
, Each turn over 450 should be treated as one 900 turn.
SEALING OF JOINTS
, All joints should be tight to avoid leaks. The male end of
each section of duct must point away from the dryer.
, Do not assemble the ductwork with fasteners that
extend into the duct. They will serve as a collection
point for lint.
, Duct joints can be made air and moisture-tight by
wrapping the overlapped joints with duct tape.
, Horizontal runs should slope down toward the outdoors
1/2inch per foot
INSULATION
Duct work that runs through an unheated area or is
near air conditioning should be insulated to reduce
condensation and lint build-up.
6