Remote Mounting Of The Control - Wired - Monogram ZVC42 Installation Instructions Manual

Custom hood inserts
Table of Contents

Advertisement

Available languages

Available languages

Installation Preparation
REMOTE MOUNTING
OF THE CONTROL - WIRED
A WARNING: Disconnect
electrical
power from unit before beginning
remote control
installation.
Failure to do so could result in personal
injurg or damage to the electrical
controls.
1-11/!6"
--
3-11/16"
Control cutout
REMOTE LOCATION
FOR CONTROL
NOTE: The hood is onlg certified for use with the
supplied 30-ft. length of wire.
The control can be removed from the hood and
installed in a backsplash
or countertop.
, A cover plate is provided to cover the opening in
the hood when the control is removed.
A 30-ft. length of 4-wire cord is supplied to
accommodate
most installations.
Because onlg
30-ft. of cord is provided, careful consideration
must be given to the location of the remotelg
mounted
control.
, The 30-ft. cord is supplied with a connector/
converter on one end. DO NOT REMOVE the
connector/converter
from the 30-ft. cord. Failure
to use the connector/converter
with the shorter
cord will prevent proper operation
of the control.
NOTE: Not for telecommunication
(telephone)
network.
, The cord must be routed through
the holes in the
insert sleeve, and the rubber grommets
put into
place around the cord.
NOTE: On the ZVC30 and ZVC36 models, the cord
needs to be routed
through
the holes in the insert
sleeve before the damper
plate is installed.
, Route the cord through
the conduit to reach the
installation
location of the control.
Remotely
Mounted
Control--Wall
or Countertop
Installation
[]
[][]
[][]
Display board
Long cord
Connector/
Short cord
converter
Main
PCB
15