ICP N9MP1 Installation Instructions Manual page 31

90+ single stage category iv furnance, fan assisted, director non-direct vent gas furnace
Hide thumbs Also See for N9MP1:
Table of Contents

Advertisement

ConcentricVentDimensional
Drawing
PVC
,ntake,C, s 0
._
A
Model
A*
B
C
381/8
3
41/2
33_/8
2
31/2
11/2"
NAHAOO1CV
NAHAOO2CV
25-22-03
D _*
211/8
16;/8
* = Dimension
will change
accordingly
as dimension
D is
lengthened
or shortened.
** = Dimension
D may be lengthened
to 60" may
also be
shortened
by cutting
the pipes
provided
in the kit to 12"
minimum
Concentric
Termination
Kit
NAHA001CV
& NAHA002CV
Venting
Table
for
*9MPD
Models
50,000, 75,000 & 80,000 Btuh Furnaces
NAHA002CV
- 35' & (4) 90 ° elbows with 2" PVC pipe or
NAHA001CV
- 65' & (4) 90 ° elbows with 3" PVC pipe
100,000 Btuh Furnace
NAHA001CV
- 35' & (4) 90 ° elbows with 3" PVC pipe or
NAHA001CV
- 65' & (4) 90 ° elbows with 3" PVC pipe &
Long Vent Kit (See Tech. Manual)
125,000 Btuh Furnace
NAHA001CV
- 35' & (4) 90 ° elbows
with
3" PVC
pipe
1, Do not include
the field
supplied
45 ° elbow
in the total
elbow
count,
2, If more
than
four
elbows
are
required,
reduce
the length
of
both
the inlet
and the
exhaust
pipes
five
feet for each
additional
elbow
used,
3, Elbows
are DWV
long
radius
type
for 2" and
3" vents.
NOTE:
Feet of pipe
is whichever
pipe
run
is the
longest,
either
inlet
or outlet
side.
5.
Partially
assemble
the
concentric
vent
termination
kit.
Clean
and cement
the parts using the procedures
for Join-
ing Pipe and Fittings
section
of the manual.
A) Cement
theY
Concentric
fitting
to
the
4"
diameter
kit
pipe.
(See
Figure
33) B) Cement
the 3" rain cap to the 21/2" diameter
kit part. (See Figure
33) NOTE:
A field supplied
stainless
steel screw
may be used to secure
the rain cap to the pipe
instead of cementing
when field disassembly
is desired
for
cleaning
(See Figure
33)
Concentric
Termination
Kit
NAHAOOICV & NAHAOO2CV Venting
Table for NDMP2 Models
50,000
& 80,000 Btuh Furnaces
NAHAOO2CV - 35' & (4) 90 ° elbows with 2" PVC pipe or
NAHAOOICV
- 65' & (4) 90 ° elbows with 3" PVC pipe
75,000 Btuh Furnace
NAHAOO2CV - 20' & (2) 90 ° elbows with 2" PVC pipe or
NAHAOO2CV - 35' & (4) 90 ° elbows with 2" PVC pipe &
Long Vent Kit (See Tech. Manual) or
NAHAOOICV
- 65' & (4) 90 ° elbows with 3" PVC pipe
100,000 Btuh Furnace
NAHAOOICV
- 35' & (4) 90 ° elbows with 3" PVC pipe or
NAHAOOICV
- 65' & (4) 90 ° elbows with 3" PVC pipe &
Long Vent Kit (See Tech. Manual)
125,000 Btuh Furnace
NAHAOOICV
- 35' & (4) 90 ° elbows with 3" PVC pipe
1. Do not include the field supplied
45 ° elbow in the total elbow
count,
2. If more than four elbows are required,
reduce
the length
of
both the inlet and the exhaust
pipes five feet for each
additional
elbow
used.
3. Elbows
are DWV long radius type for 2" and 3" vents,
NOTE: Feet of pipe is whichever
pipe run is the longest,
either
inlet or outlet side,
If assembly
needs to be extended
to meet height or side wall thick-
ness requirement,
the two pipes supplied
in the kit may
be re-
placed
by using
the same
diameter
solid,
single
(no coupling
connections)
field supplied
SDR-26
PVC (ASTM
D2241)
pipes.
Do not extend
dimension
D more than
60". (See Figure
32)
Do not
use
field
supplied
couplings
to extend
the
pipes.
Airflow
restriction
will occur
and the furnace
pressure
switch
may
cause
intermittent
operation.
25-22-02
Rain Cap to Vent Pipe Assembly
Drill clearance hole in rain
capand p_t
pipe.
Stainless
steel screw
(Field supplied)
CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning
could result in death
or personal
injury.
When using the alternate screw assembly
method,
drill a clearance hole in the rain cap and a pilot hole
in the vent pipe for the screw
size being
used.
Failure to drill adequate holes may cause cracking
of the PVC components,
allowing
flue gases to be
recirculated.
44001 102102