CHAPTER 4 ADVANCED FUNCTION SETTINGS
4-1 Auto Power off and Backlight Setting
Switch on the scale, press
function setting mode. The display shows
Auto power-off setting
Press the
ON/ZERO
to enter a parameter
Press the
key
TARE
Press the
ON/ZERO
to enter a parameter
ON/ZERO
Increment digit (from 0 to 9)
TARE
Confirm / enter key
NET/GROSS
Move the cursor to the right
Automatic power-off function
When the weight on weigh pan is less than 10d or remains steady for the set time, the scale
will automatically switch off.
v Automatic power-off is not functional, when using an ac adaptor as the power source.
Therefore, auto power-off is ONLY active, when using dry batteries as the power source.
Auto Backlight Function
When the weight is over 10d, the backlight is on. After the weight is stable for 10 seconds or
when the scale returns to zero, the backlight switches off.
Ocean User Manual
ON
and
ZERO
key
key
.
NET
keys together to enter the advance
GROSS
The display shows the last setting
Auto power off timer setting
Press the
ON/ZERO
0
No auto power-off
1
When the scale is idle for 1 minute, the
scale automatically switches off
2
When the scale is idle for 2 minutes, the
scale automatically switches off
19
When the scale is idle for 19 minutes, the
scale automatically switches off
The display shows the last backlight setting
Auto backlight setting
Press the
ON/ZERO
on
Auto Backlight on
off
Auto Back light off
8
.
key to enter a parameter.
key to enter a parameter.
SME300000132
Need help?