6.2 Setting Syntax

6.2.1 Manufacturing Default:
Datum: WGS84.
Baud Rate: 4800.
Output: GGA, GSA, GSV, RMC.
6.2.2 Datum change syntax:
>DOS\Sirfprog /Fdataxx.dat –Px –Bx –Csh1
-Px: x is com port, 1= COM1, 2 = COM2
-Bx: Baud rate, 4800, 9600, 19200 or 38400
Example:
Change Datum to WGS84,
Sirfprog /Fdata58.dat –P1 –B4800 –Csh1 <Entry>
After changing datum, the new datum will be kept in SRAM. If no power supplied to GR-211 for more
than 30 days, user must re-set datum when power on.

7. Ordering Information

7.1 Product Options

Explanation of product Number
G R – 211 -X – Y
(1)
(1) Model name:
(2) X : Appearance Type
H: GR-211H
P: GR-211P
(3) Y: Output Type option
1: RS232+TTL
2: RS232 + DGPS
Model
GR-211-X-1
GR-211-X-2
(1) Standard accessories type list below and other type please contract factory.