INSTALLATIONOF NATURALGAS
ORIFICE SPUDS
6 BURNER MODEL (45" WIDE)
ARMY
YELLOW
SILVER
GREEN
ARMY
SILVER
GREEN
FIGURE 13
HOLDING UNIT DOWN TO COUNTERTOP
Positionthe cooktopin the cutout opening.Pre-threadholddown bolts
approximately2 inches into hold-downstraps. (2 each suppliedwith
4-burner model,4 eachsupplied with 6-burnermodel).Opencabinet d oors,
then reachup undercooktopand install hold-downbracketsinto slots in
eachendof burnerbox(seefigure15).Thetopof eachbracketshouldhook
intotheslot asshown.(Repeat f or frontand rearof6 burner-burner model.)
Tighten the bolt in each bracketto snug the unit top down against the
countertop. Seefigure 16. DO NOTOVERTIGHTEN.
(BOTH
ENDS)
_URE
15
BURNERIGNITION AND AUTO-REIGNITION
This applianceis equippedfor electronicauto-reignitionby means of a
spark igniterlocatedat the rearof each burner.The burnersaredesigned
tolightat anyvalverotation that admitssufficientgasflowto supportaflame
andto automaticallyretight f ollowinga tossofflame dueto a draft or other
adversecondition.This feature is providedas a convenienceand is not
intendedas a safetyfeature.
CAUTION: Never use a metal blade to pry off a control knob. tf a knob
cannot be easily removedtuck the folds of a cloth dishtowelunder and
aroundthe knoband pull the towel upwardwith steadyeven pressure.
CAUTION:Nevercover controlknobsorsurroundingcontrolsurfacewith
utensils,towels, or otherobjects.Neverobstructfree air passagepastthe
controlknobs.The knobopeningshavebeensized to properlycontrolair
entry to the interiorof the applianceduringoperation.
This appliance has no air shutters. Primary air adjustments are
unnecessary. Theburnersaredesignedto provideoptimumaerationforall
gases without air shutters. When operating properly, burners should
produceclearlydefined,evenblueflames. If theflameshaveyellowtips or
are hazy andotherwiseappearto haveinsufficientair,obtainthe services
of a qualifiedservicetechnician.
Specifiedinputrates are as shownin figure14 below.
BURNER
LOCATION
Right Front
Right Rear
CenterFront
CenterRear
Left Front
Left Rear
INPUT RATES- NATURALGAS (BTU/HR)
Hi
Lo
15,000
1,500
9,100
1,100
6,500
850
6,500
850
9,100
1,100
10,500
1,500
FIGURE 14
HOLD-DOWN
STRAP
FIGURE 16
REQUIRED ADJUSTMENTSAT TIME
OF INSTALLATION
The installationof this appliancemustconformwith localcodes,or in the
absenceof local codes,with the latest editionof the National FuelGas
Code ANSI Z223.1 USA or current CAN!CGA-B149INSTALLATION
CODE.
[1
Thisappliancewas manufactured for usewith NaturalGas.tf LPgas
isthefuelofchoice,followtheconversion to LP procedure foundin the
installationinstructions.
[N Testall externalconnections for gas leaks.Nevertest for gas leaks
with an openflame.
[1
Testall electricalconnections.