Spa Equipped Safety Devices - L.A. Spas 2010 North American Owner's Manual

Entry-level spa
Table of Contents

Advertisement

Your spa is equipped with the following safety features:
1.
Overheat Protection – A water temperature sensor circuit in the system will monitor the water
temperature. If the temperature reaches 112°F (44°C), the pump and all accessories will shut off.
The spa will resume normal operation when the water temperature drops to 109°F (42°C).
2.
Heater High Limit Protection – If the water temperature reaches 119°F (48°C) as determined by
the water temperature sensor circuit, the pump and all accessories will shut off. The spa will
resume normal operation when the water temperature drops to 109°F (42°C) and a key press to
clear the fault.
3.
Heater Dry Run Protection – The system will prevent the heater from turning on if it determines
that there is not enough water flow to operate the heater.
4.
Freeze Protection Mode – The freeze protection system will activate at 44°F (6.6°C). The system
will turn on the low speed pump and heat to the set temperature. The spa will resume normal
operation upon reaching a temperature of 45°F (7.2°C).
5.
Timeouts – The pump will turn off automatically after 30 minutes of continuous operation. The
light will turn off automatically after 4 hours of continuous operation.