ELECTRICAL SYSTEM
Symptom
Spa will not turn on in any
mode
Spa turns on by itself
Light is out
Pump shuts down
unexpectedly while in use
ERROR CODES
Error Code
Input frequency (50/60Hz) is out of range.
FrEr
Input voltage is too low.
SP1n
Fuse #1 is blown.
spf1
Fuse #2 is blown.
spf2
Fuse #3 is blown.
spf3
Internal temperature of the control pack is
SPOt
too high.
Spa water is above 112°F (44°C)
SPOH
A hardware error was detected in the heater.
rHHr
Occurs when heater tries to heat the water,
rHnH
but does not detect any temperature rise.
Occurs when a "no flow" condition is
detected by the heater.
rHnF
The high limit circuit has tripped.
rHHL
Problem
1. No power
2. Equipment malfunction
1. Normal automatic daily filtration
cycle
2. Spa required heat to maintain
temperature
3. Freeze protection engaged
4. Equipment malfunction
1. Automatic time out has shut off
light
2. Burned out light bulb
1. Automatic timeout has shut pump
off
2. Motor overheated and protective
device has shut down pump
Description
1. Check circuit breaker and/or
GFCI
2. Call for service
1. No action required
2. No action required
3. No action required
4. Call for service
1. Press Light key again to start
another cycle
2. Replace light bulb
1. Press Jets keys again to start
another cycle
2. Allow pump to cool. If the
pump does not restart when
Jets key is pressed, call for
service.
Contact a certified electrician to verify
the power line quality.
Check connections at control pack. Call
a certified electrician to verify power line
quality.
Turn off power. Replace blown fuse
with identically rated fuse.
Turn off power. Replace blown fuse
with identically rated fuse.
Turn off power. Replace blown fuse
with identically rated fuse.
Remove front cabinet panel and allow
the equipment to cool. Reset power to
spa.
Remove spa cover and allow the water
to cool. Add cold water if necessary.
Reset power to spa. Check for heater
operation by changing the set
temperature. If error code remains, call
for service.
Check for loose connection of heater
cable. Reset power to spa. If error
code remains, call for service.
Reset power to spa. Make sure that the
pump associated to the heater is
running. Check and clean filters. Air
locked, prime the pump (see page 14).
Add cold water to spa and let the heater
cool down, reset power to spa.
27
Corrective Action
Corrective Action
rev. 2012v1