7.4

Real time operation

7.4.1
7.4.2
1003090-EI-2.0
Manual operation "Cleaning position" 07
The door rotates forward as long as the + key is hold down and backwards as long
as the - key is hold down.
Note: During manual operation safety devices are disconnected.
+
-
Programming of real time operation must be done by Besam service engineer. Fill
in form on page 34.
The CDC-system has three different day schedules. Each day schedule may con-
tain up to 10 different operation modes. The week schedule informs the system of
which day schedule to run and in what order during a week. It is possible to make
up to 16 exceptions from this week schedule for e.g. public holidays etc.

Activation

1. Type F556 (Real time operation ON).
1
2
1
1
1
2
1
0
F556 =
9
3
8
4
7
5
ILL-00181
6
2. Prompt P3 lits up.
ILL-00193
3. The door operates according to schedule.

Deactivation

1. Type F557 (Real time operation OFF).
1
2
1
1
1
1
0
2
F557 =
9
3
8
4
ILL-00192
7
5
6
2. Prompt P3 lits down.
ILL-00193
3. The door operates according to manually set operation mode.
Issued 2006-12-21
ILL-00191
Programme selector PCD