This manual contains necessary details and instructions for the daily use of the Besam revolving door RD3/RD4. Besam RD3/RD4 is designed to offer continuous use, a high degree of safety and maximum lifetime. The system is self-adjusting to the effects caused by normal variations in the weather conditions and to minor friction changes caused by e.g.
Service Service When your door needs to be serviced, contact the nearest authorized Besam service centre. Place for telephone number, stamp, sticker or the like. We recommend inspection of doors at least once a year (see page 23). According to regulations inspection of emergency escape doors is required at least twice a year, carried out by an authorized service centre.
Main parts Main parts Description Programme selector and reset push-button Emergency stop push-button Activation unit 1003090-EI-2.0 Issued 2006-12-21...
Operation Operation Programme selector The programme selector is equipped with a three position key switch and a reset push-button. Note! If the door is equipped with a PCD programme selector, (see page 13). Start up • Open the night security doors, if fitted •...
Operation Switch off • Check there is no traffic • Turn the programme selector to off position The door rotates to its home position The electro-mechanical lock, if fitted, is locked • Lock the mechanical lock, if fitted • Close and lock the night security doors, if fitted Reset •...
Safety equipment Safety equipment ILL-00043 Standard Description Compressible safety switches placed on the drum edges (see page 11) Force sensitive door leaves (see page 11) Emergency stop push-button (see page 12) Options Description Compressible safety switches placed on the door leaves (see page 24) Infrared presence sensing system (see page 24) Vertical presence photocell sensor PDR (see page 25) Break-out kit (see page 25)
Safety equipment Standard 6.1.1 Compressible safety switches Compressible safety switches on the drum edges. These stop the rotation if com- pressed. When the obstacle is removed, the rotation continues. 6.1.2 Force sensitive door leaves • If the system detects an obstacle blocking the door, the power to the motor is shut-off •...
Safety equipment 6.1.3 Emergency stop push-button • The door rotation can be stopped by pressing the emergency stop push-button • To reset the door to normal operation - release the emergency stop push-button by rotating it in any direction and press the reset push-button or the C push- button on the PCD (if installed) ILL-00044 ILL-00049...
Programme selector PCD Programme selector PCD As option the RD3/RD4 can be equipped with programme selector PCD (pro- gramme control device) with access codes to operate the door. General information Function Numeric inputs Confirm access code input Setpoint selection upwards...
Programme selector PCD Access code To be able to operate the PCD a login of access code must be done. 7.2.1 Login to the PCD 1. Type # to clear the display. 2. Type the access code, delivery code 1234, with the number key (four digits). The display shows ==.
ILL-00175 If the door is locked with the ON/OFF switch it can be opened with a key impulse switch (ask your local Besam Service). When the key impulse switch is activated, the door unlocks, runs 360° and locks again. Changing operating mode 1.
Programme selector PCD 7.3.1 The different operating modes Closed (locked) 01 The door rotates to its closed position. If an electromechanical lock is fitted, the lock is activated. The door can be opened with the key impulse switch, see “The ON/OFF switch”...
Note: During manual operation safety devices are disconnected. ILL-00191 Real time operation Programming of real time operation must be done by Besam service engineer. Fill in form on page 34. The CDC-system has three different day schedules. Each day schedule may con- tain up to 10 different operation modes.
Programme selector PCD 7.4.3 ON/OFF The OFF position overrides real time operation. The door will be locked. When the key switch is ON, the door resume settings according to schedule. EAA204 7.4.4 Manually setting of operation mode If the door is running in real time operation mode and the operation mode is man- ually changed, real time operation mode is automatically deactivated.
Programme selector PCD Read speed settings 1. Type F3. The display shows S1. 2. Use ↑ or ↓ to select setpoint number to read. 3. Press C to leave the menu. ↑/↓ FUNC DATA EAA254 Setpoint Description Setpoint value High speed setpoint 1.0-6.0 rpm Low (handicap) speed setpoint 0.2-2.5 rpm...
To operate the door and have service control the CDC system can be connected to a computer via the RS 232 connection “Read out”. It can be connected directly or via a modem. Ask your local Besam distributor for more information. Com. port MODEM...
7.7.1 Communication ON/OFF To allow/not allow this, the communication command has to be set to ON or OFF. If no PCD is installed talk to your local Besam Service. External communication ON Type F552 on the PCD. External communication OFF Type F553 on the PCD.
Programme selector PCD Door operation Error/Status Display: Operating Mode: Real Time Mode 1 Door Speed (RPM/10): Revolution Counter: 35552 Date & Time: Monday 2005-06-13 13:07:16 Operating modes: 1: Lock Door 2: Auto Open = Start from open position 6: Continuous Rotation 7: Manual Operation Press function key: C: Error Clear...
Maintenance Maintenance The fascia, windows and profiles must be subjected to regular inspection and cleaning, the frequency of which is governed by the environmental conditions (at least three times a year). Cleaning To maintain the quality of the enamel layer, the surfaces shall be cleaned three times/year (once/four months period) with gentle (pH 5-9), non-polishing deter- gent and water.
Options Options Compressible safety switches on the door leaves If one of the safety switches, mounted on the door leaves, is compressed, the door stops. When the obstacle is removed, the rotation starts. Infrared presence sensor Installed on the top of the door leaves provides safety over the whole height of the door.
Options Vertical presence photocell sensor PDR Vertical presence photocell sensor PDR located above the entrance on inner and outer sides. If the beam is broken in the safety zone (approx. 25° from the drum edge) the door stops. When the obstacle is removed the rotation starts. Break-out kit Enables the door leaves to be broken outwards in case of emergency.
Options Push-button for disabled Push-button to reduce speed of the door. ILL-00050 Push-button inside door In case somebody is trapped in a compartment, the door can be opened by push- ing this button, placed inside on the mid post. Issued 2006-12-21 1003090-EI-2.0...
Accessories 10.0 Accessories 10.1 Rotation brake (lock) The rotation brake, brakes the door in parked position. The brake can also be acti- vated with a key switch or push-button for immediate stop of the door. ILL-00052 10.2 Electromechanical lock The electromechanical lock, locks the door in home position. ILL-00051 1003090-EI-2.0 Issued 2006-12-21...
Accessories 10.3 Direction sensing radar DSR The radar DSR is direction sensing i.e. it triggers an opening impulse for approaching objects only, but not for objects leaving the door. 10.4 Night closing door NCD Two versions are available: • manually operated •...
11.0 Troubleshooting 11.1 Supervision system The RD3/RD4 has a built-in supervision system. If an error occurs, the PCD display will show an error or status code. During nor- ON” mal operation the display will show “ . All error codes are shown by flash- ing figures, status codes with permanent figures.
After checking press C Power fail input Main power lost Check main fuse. Check external power supply For all other error codes call Besam Service. Issued 2006-12-21 1003090-EI-2.0...
Troubleshooting 11.4 Status codes 11.4.1 Diagnostic out-put It is possible to monitor the system by looking at the red and yellow out-put LED’s on the control unit CDC. Cause I/OA-1 (red LED) I/OA-2 (yellow LED) Safety stop Fixed light Emergency stop Fixed light Blocked door Fixed light...
Mark up table 12.0 Mark up table 12.1 Floor levelling information from installation 12.1.1 Floor surface levelling values ILL-00196 Point Point 1 value Value Deviation Issued 2006-12-21 1003090-EI-2.0...
Real time operation 14.0 Real time operation Day schedule Day schedule 1 Day schedule 2 Day schedule 3 Week schedule Week day Schedule Monday Tuesday Wednesday Thursday Friday Saturday Sunday Exceptions Start exception End exception Exception schedule Issued 2006-12-21 1003090-EI-2.0...
Page 35
Real time operation 1003090-EI-2.0 Issued 2006-12-21...
Page 36
Fax: 44 53 20 22 besam@besam.dk Besam Production AB, Box 668, SE-261 25 Landskrona. Tel: +46 418 512 00 Fax: +46 418 512 68 general@besam.se • www.besam.com ASSA ABLOY is the world's leading manufacturer and supplier of locking solutions, meeting tough end-user demands for safety, security and user friendliness.