Manual English | Français | Español Jandy Pro Series ® JE Heat Pump WARNING For Your saFEtY - This product must be installed by a licensed HVAC technician certified in heat pump repair and maintenance by the jurisdiction in which the product will be installed where such state or local requirements exists.
® Jandy Pro Series JE Heat Pumps Installation and Operation Manual ENGLISH Page 1 table of Contents section 1. General information ....3 Operating Features of Hybrid Units with Optional Chiller ..........19 Introduction ............3 User Setup Options .......... 20 Consumer Information and Safety ......
Page 4
® Jandy Pro Series JE Heat Pumps Installation and Operation Manual Page 2 ENGLISH...
Safety Commission, should be observed when 2620 Commerce Way using the spa. Vista, CA 92081 USA The Jandy Pro Series JE heat pump gets electrical power WarninG from an external source and provides a dual digital Spa or hot tub water temperature should never thermostat control system for pool/spa combinations or exceed 104°F (40°C).
Warranty Symptoms include dizziness, fainting, drowsiness, lethargy, and an increase in the internal body The Jandy Pro Series JE heat pump is sold with a temperature. The effects of hyperthermia include: limited factory warranty. Make all warranty claims to your Zodiac ®...
If the heat pump is to be installed in a garage or under technical specifications a vertical overhang, the unit must have a minimum of See Table 1 for the Jandy Pro Series JE heat pump 5 feet (1.5 meters) clearance from the top of the heat pump.
Page 8
® Jandy Pro Series JE Heat Pumps Installation and Operation Manual Page 6 ENGLISH...
® Jandy Pro Series JE Heat Pumps Installation and Operation Manual ENGLISH Page 7 Figure 1. Jandy pro series JE Heat pumps dimensions MODEL SIZE DIMENSIONS JE1500T 33” 34” 12.5” 9” 7” 39” JE2000/2500T 36” 40” 13.8” 19” 15” 43”...
® Jandy Pro Series JE Heat Pumps Installation and Operation Manual Page 8 ENGLISH To install the anchor clamps: (800) 822-7933 for details. Be advised that when pool equipment is located Be sure that the heat pump is in its permanent below the pool surface a leak can result in large scale location on the equipment pad.
® Jandy Pro Series JE Heat Pumps Installation and Operation Manual ENGLISH Page 9 EVAPORATOR ATTACH ANCHOR BRACKETS COIL TO BASE OF HEAT PUMP WHERE INDICATED #10 X 5/8" STAINLESS STEEL SCREW HEAT PUMP ANCHOR HEAT PUMP BRACKET PLASTIC BASE 1/4"...
Label all wires prior to disconnection when must be done by a certified electrician. servicing controls. Wiring errors can cause The following is the procedure to wire the Jandy Pro improper and dangerous operation. Verify proper Series JE heat pump to the electrical source specified on operation after servicing.
Installation and Operation Manual ENGLISH Page 11 VENT FOR INDOOR INSTALLATION ONLY POOL HEATER CHEMICAL LOOP OR OPTIONAL CHLORINE GENERATION SYSTEM (JANDY AQUAPURE ® SHOWN) CHEMICAL FEEDER FILTER POOL PUMP FROM POOL OR SPA CHECK VALVE TO POOL OR SPA MANUAL BYPASS VALVE Figure 4.
® Jandy Pro Series JE Heat Pumps Installation and Operation Manual Page 12 ENGLISH Optional Isolation Valves 2” PVC From Filter 3” PVC Manual Bypass Valve To Pool Figure 6. two (2) Heat pump plumbing layout Optional Isolation Valves 2” PVC From Filter 3”...
® Jandy Pro Series JE Heat Pumps Installation and Operation Manual Page 14 ENGLISH Figure 9. Jandy pro series JE 3-phase Electrical supply Wiring diagram...
SERVICE ACCESS HIGH VOLTAGE WIRES PANEL (5 SCREWS) CONNECTOR FOR LOW VOLTAGE WIRES Figure 10. Jandy pro series JE Heat pump Front View Bonding panel to the heat pump unit and the cover to the junction box (see Figure 10). Caution...
(4 wire) Connection to aqualink ® into the ON position (see Figure 12). Confirm the Jandy Pro Series JE heat pump and install the remote tstat AquaLink RS software revisions are compatible. Turn off the power to both the pool/spa control system and the heat pump unit.
RS6 & RS8 ONLY RS8 ONLY RESET POOL MODE SPA MODE AUTO SPA DRAIN SERVICE HEATER SOLAR SPA FILL TIME OUT DIP Switches S1 and S2 Figure 12. aqualink rs to Jandy pro series JE Heat pump - t-stat (2 wire) connection...
Immediately call a qualified operating the Controller service technician to inspect the heater and Your new Jandy Pro Series JE heat pump is controlled replace any part of the control system which by an advanced microprocessor based controller that has been under water.
® Jandy Pro Series JE Heat Pumps Installation and Operation Manual ENGLISH Page 19 set point. After 5 seconds of inactivity, the new set point spa Mode - (normal Heat) is stored in memory. When the water temperature rises To enable the spa mode, press spa . The associated left...
® Jandy Pro Series JE Heat Pumps Installation and Operation Manual Page 20 ENGLISH spa timer setup user setup options The User Setup options allow the user to select specific Make sure the control is in the oFF mode. Languages, Temperature Scale, Spa Timer, and Display To enter the User Setup mode, press and hold the Light options.
® Jandy Pro Series JE Heat Pumps Installation and Operation Manual ENGLISH Page 21 If the heat pump control displays “NO FLOW”, set point lockout then the flow in the system may be below the Make sure the control is in the on mode (pool or...
® Jandy Pro Series JE Heat Pumps Installation and Operation Manual Page 22 ENGLISH ments. Perform the following steps to completely drain Zodiac recommends that you inspect your heat pump the heat pump (see Figure 15). on a regular basis and especially after abnormal weather conditions.
® Jandy Pro Series JE Heat Pumps Installation and Operation Manual ENGLISH Page 23 Inspect the electrical controls, specifically the notE The maximum heat output and efficiency of a heat pump is dependent upon the quality following: and performance of the major components a.
® Jandy Pro Series JE Heat Pumps Installation and Operation Manual Page 24 ENGLISH section 8. troubleshooting troubleshooting Guide The following table provides symptoms and solutions for general troubleshouting problems for the heat pump. table 4. Heat pump troubleshouting Guide...
® Jandy Pro Series JE Heat Pumps Installation and Operation Manual ENGLISH Page 25 diagnostics In the event a pressure switch opens or another fault condition occurs, the LCD screen will display the fault until the problem has been resolved. Please refer to the following table for the list of diagnostic conditions.
® Jandy Pro Series JE Heat Pumps Installation and Operation Manual Page 26 ENGLISH section 9. replacement parts ordering information To order or purchase parts for the JE models of heat pumps, contact your nearest Zodiac dealer or distributor. See the Zodiac web site at www.Zodiac.com for the nearest service center.
® Jandy Pro Series JE Heat Pumps Installation and Operation Manual ENGLISH Page 27 Zodiac ® JE 1500 Heat pumps Exploded View *See Figure 19 for detail DETAIL C SCALE 1 : 8 Figure 16. Zodiac JE Heat pumps Exploded View (JE1500 shown)
® Jandy Pro Series JE Heat Pumps Installation and Operation Manual ENGLISH Page 29 Zodiac ® JE single phase Electric Box JE1500 ONLY Figure 18. Zodiac JE single phase Electric Box Zodiac ® JE three phase Electric Box Figure 19. Zodiac JE three phase Electric Box...
Page 32
Zodiac Pool Systems, Inc. 2620 Commerce Way, Vista, CA 92081 1.800.822.7933 | www.ZodiacPoolSystems.com Etl listEd ConForMs to ul std 1995 Zodiac Pool Systems Canada, Inc. CErtiFiEd to Can/Csa C22.2 no.236 2115 South Service Road West, Unit 3 Oakville, ON L6L 5W2 1-888-647-4004 | www.ZodiacPoolSystems.ca ZODIAC ®...
Need help?