Table of Contents Table of Contents 1. Before You Begin ....................1 What Is Included ......................1 Unpacking Instructions ....................1 Claims ........................... 1 Typographic Conventions ....................1 Icon Indications ......................1 Product at a Glance ....................... 2 Safety Notes ........................2 Personal Safety ........................
Page 4
Table of Contents Auto/Custom/Fan ......................... 12 Dimmer Speed ........................12 Menu Map ........................13 DMX Values ........................14 TOUR ..........................14 TOUR (Cont.) ........................15 BLOCK1 ..........................16 BLOCK2 ..........................16 ARC1 ........................... 16 ARC1 + D..........................16 ARC3 ........................... 17 ARC3 + D ..........................17 ARC3 + S ..........................
If the box or the contents (the product and included accessories) appear damaged from shipping, or show signs of mishandling, notify the carrier immediately upon receipt, not CHAUVET®. Failure to notify the carrier in a timely manner may invalidate your claim. In addition, keep the container and all the packing material for inspection.
There are no user-serviceable parts in this product. Any reference to servicing in this User Manual applies only to properly certified CHAUVET® technicians. Do not open the housing or attempt any repairs unless you are certified by CHAUVET®. Please refer to all applicable local codes and regulations for proper installation of this product.
Introduction 2. Introduction Product The COLORado™ Batten 144 Tour is an RGBWA linear LED wash light. It consists of a single module that accommodates the internal power supply, the main control, the control Description panel, the LED drivers, the LED boards and lenses as well as the power and signal connectors.
Introduction Product Overview Control Panel- Safety Eye Bolt 5-Pin DMX In/Out 3-Pin DMX In/Out Fuse Power In Power Out COLORado™ Batten 144 Tour User Manual Rev. 2...
The listed current rating indicates the maximum current draw during normal operation. For more information, download the document Sizing Circuit Breakers from the CHAUVET® website: www.chauvetpro.com. Never connect this product to a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel serves only as a 0% to 100% switch.
If you are not familiar with or need more information about DMX standards, Master/Slave connectivity, or the DMX cables needed to link this product to a DMX controller, download the DMX Primer from the CHAUVET® website: www.chauvetpro.com. DO NOT connect a DMX controller to products operating in Master/Slave mode. The DMX controller signals may interfere with the signals from the master product.
Always mount this product in a safe position and make sure there is adequate room for ventilation, configuration, and maintenance. Rigging CHAUVET® recommends using the following general guidelines when mounting this product. • When selecting an installation location, consider easy access to this product for operation, programming adjustments, and routine maintenance.
Operation 4. Operation Control Panel Button Function Description <MENU> Exits from the current menu or function Enables the currently displayed menu or <ENTER> sets the currently selected value in to the current function Navigates upward through the menu list and <UP>...
Operation Static Color The Static Color mode allows for permanent RGBWA color mixing without a DMX controller. 1. Go to the STATIC main level. 2. Select the desired color (RED, GREN, BLUE, WHIT, or AMBE). 3. Select the desired color value (000~255). 4.
Operation Color Settings The COLOR setting determines how the COLORado™ Batten 144 Tour generates the white color based on various RGB settings. 1. Go to the SETTINGS main level. 2. Select COLOR. 3. Select OFF, RGB TO W, or UC. OFF: When all the RGB faders are set to 255, the output is maximum, although the resulting white color may not be balanced.
Operation DO NOT upload the data from a COLORado™ Batten 144 Tour to a different product. The other product may become inoperative. Reset This setting allows you to reset the COLORado™ Batten 144 Tour to the default values, including the custom programs. 1.
Operation • Channel 7 has priority over channels 2 through 6. • Channel 1 controls the intensity of the Color Macro. • Channel 8 controls the strobe frequency (not the intensity) of channels 2 through 7. Strobe • Channel 8 can strobe channels 2 through 6 when not running macros, allowing the individual faders (R, G.
Operation Menu Map Main Level Program Levels Description GREN User can combine Red, Green, Blue, White, and BLUE 000~255 Amber to generate a custom color STATIC WHIT AMBE STRB 00~20 Select a strobe frequency AUTO Choose from 10 automatic programs AUTO 01~10 000~255...
Operation DMX Values TOUR Channel Function Value Percent/Setting 000 255 000~100% Master Dimmer 000~100% 000 255 (Step Time when playing custom 01~10) 000~100% 000 255 Green (Fade Time when playing custom 01~10) 000 255 000~100% Blue 000 ...
Operation TOUR Channel Function Value Percent/Setting (Cont.) 000 010 No Function 011 020 Fans Off 021 025 Fans Low 026 030 Fans High 031 040 Fans Auto 041 050 Auto 1 051 060 Auto 2 061 ...
Technical Information 5. Technical Information Product To maintain optimum performance and minimize wear, you should clean this product frequently. Usage and environment are contributing factors in determining the cleaning Maintenance frequency. As a rule, clean this product at least twice a month. Dust build-up reduces light output performance and can cause overheating.
Faulty Display/Main board Send product for repair If you still experience technical problems after trying the above solutions or if you need to send the product for repair, contact CHAUVET® Technical Support. COLORado™ Batten 144 Tour User Manual Rev. 2 -19-...
Be sure to pack the product properly. Any shipping damage resulting from inadequate packaging will be the customer’s responsibility. Proper FedEx packing or double-boxing are the packaging methods CHAUVET® recommends. CHAUVET® reserves the right to use its own discretion to repair or replace returned product(s). Contact Us World Headquarters United Kingdom &...
Technical Information Technical Specifications Dimensions and Length Width Height Weight Weight 5.2 in (132 mm) 39.3 in (998 mm) 8.2 in (209 mm) 19.6 lbs (8.89 kg) Note: Dimensions in inches rounded to the nearest decimal digit. Electrical Power Supply Type Range Voltage Selection Switching (internal)
Need help?
Do you have a question about the COLORado Batten 144 and is the answer not in the manual?
Questions and answers