CAP600 REV C APRIL 2013 CA/CT Series TWO STAGE RECIPROCATING AIR COMPRESSORS Installation and Operations Manual...
Page 2
The model # is found on the tank decal and the serial number is located on the compressor nameplate. For Customer Service, Technical Service, or to order replacement parts, please contact your local distributor. FS Curtis, Inc. 1905 Kienlen Avenue, St. Louis, Missouri 63133 phone: 1-800-925-5431 fax: 314-381-1439 email: info@curtistoledo.com...
CA / CT SERIES CAP600 Page 2 of 30 REV D July 2013 Table of Contents Read Me First Section 1 Safety Precautions ......................3-4 System Diagram ....................... 5-6 Installation Section 2 Receiving ..........................7 Freight Damage ........................8 Installation Procedure ....................9-12 Post Installation Checklist....................13 Electrical Requirements .....................14 Wiring Diagrams...
FS Curtis, Inc. neither states as fact, nor in any way implies that this list of safety precautions is an all-inclusive list, the observance of which will prevent all damage to property or injury to personnel.
Page 5
Do not use plastic pipe, unapproved rubber hose, or lead-tin soldered joints in any part of the compressed air system. Alterations must not be made to this compressor without FS Curtis’ expressed, written approval. Do not operate the compressor in excess of the A.S.M.E. pressure vessel rating for the receiver or the service rating of the compressor, whichever is lower.
Fig. (1) Simplex, two stage air compressor process. FS Curtis manufactures a broad array of compressor configurations to satisfy the needs of our diverse customer base. Despite this diversity, all FS Curtis two stage compressor configurations work off the same basic cycle. Air is drawn into the compressor through the air intake and filter assembly.
Page 7
CA / CT SERIES CAP600 Page 6 of 30 REV D July 2013 Duplex Units Exact orientation of your system's Air Intake Alternator components may be different from the Air Compressor Pressure Switch layout in the figure. Please see your model's general arrangement diagram for a precise Vibration Isolator pads Intercooler...
FS Curtis strongly recommends that any or all person(s) in charge of installing, maintaining, or servicing one of our compressors read and understand the entire contents of this manual and the respective compressor installation and operating instruction manual in order to perform such duties safely and efficiently.
CA / CT SERIES CAP600 Page 8 of 30 REV D July 2013 FREIGHT DAMAGE The transportation industry has adopted a modification with regard to the handling of obvious and concealed damage claims. Therefore, it is extremely important that you examine every carton and crate as soon as you receive it.
The unit should never be operated at ambient temperatures above 104° F or below 32° F. If the ambient temperature is below 40° F, FS Curtis recomm ends using Arctic oil. Maintenance checks are required daily, thus three (3) feet of space needs to be provided around the compressor for proper inspection.
Page 11
If you wish to utilize an installation method other than the approved methods described in Table (2), please contact your local distributor. FS Curtis neither states as fact, nor implies that the above list of Acceptable/Unacceptable mounting is all-inclusive. Contact your local distributor for more information.
Page 12
CA / CT SERIES CAP600 Page 11 of 30 REV D July 2013 Recommended Installation – Use concrete anchor bolt Fig. (6) Recommended Installation Method Mounting bolt, see Table (3) for recommended sizes Flat washer, sized for bolt Compressor Base Vibration Isolator Pads Steel Shim (as necessary for leveling) Concrete floor, see local codes for recommended...
Page 13
Run a clean pipe to the tank discharge opening, bushing up or down as necessary with clean bushings and fittings. Note that the more bushings and fittings placed in the air distribution system, the greater the opportunity for air leaks and breaks. FS Curtis recommends the installation of drip legs in the distribution piping.
1. Remove all installation tools from the compressor and check for installation debris. Abrasive dust can seriously damage the air intake and belt assemblies. 2. All FS Curtis compressors are shipped from the factory filled with the required amount of Curtis Lube Plus Compressor Lubricant specially formulated for Curtis Compressors. The oil level should register in the center of the oil sight glass or between the high and low marks on the dipstick.
National Electrical Code (N.E.C.), O.S.H.A. code and/or any local or state codes having precedence. All FS Curtis compressors come with a factory installed, pre-wired starter, if you wish to provide your own starter, please contact your local distributor for more information. Check the electrical supply for voltage, phase, and frequency to see that they match the nameplate stampings on the motor, magnetic starter, solenoids, and other controls.
CA / CT SERIES CAP600 Page 15 of 30 REV D July 2013 Wiring Diagrams: Simplex Single Phase and 3 Phase TURN OFF / TAGOUT POWER BEFORE SERVICING 1 L3 2 L2 3 L1 4 Overload relay 5 Reset switch Fig (7) Simplex Starter Motor Motor...
CA / CT SERIES CAP600 Page 16 of 30 REV D July 2013 Wiring Diagrams: Duplex Dual Source Alternator TURN OFF / TAGOUT POWER BEFORE SERVICING 1 L1 2 L2 3 L3 Fig (10) Duplex dual source alternator panel. NOTE: Unit wiring diagram is located on the inside front cover of the alternator panel. If, over time, the diagram becomes illegible, please contact your local distributor.
If there are any questions regarding any part of the instructions, please call your local FS Curtis distributor. With the pre-starting checklist completed and satisfied, close the disconnect switch and start the compressor (for electric units) or engage the starter (for gas units).
CA / CT SERIES CAP600 Page 18 of 30 REV D July 2013 For the first weeks, the compressor needs time to “break in.” The belt requires time to stretch and fit into the surface of the pulleys. The piston rings need time to seat themselves into the cylinder walls, and bearings need to wear into place.
CA / CT SERIES CAP600 Page 19 of 30 REV D July 2013 Maintenance Shut Down Procedure The following procedures should be followed when stopping the compressor for maintenance or service. WARNING! Never assume a compressor is safe to work on just because it is not operating. It could start at any time.
CA / CT SERIES CAP600 Page 20 of 30 REV D July 2013 Maintenance Schedule To assure maximum performance and service life of your compressor, a routine maintenance schedule should be developed. A sample schedule has been included to help you develop a maintenance schedule designed for your particular application.
Air Compressors. Non-Detergent type with anti-foam, anti-rust and oxidation inhibitors. Under normal operating temperatures, use FSC-1000 ISO68 CURTIS-LUBEPLUS. In areas with very hot ambient air temperatures, FS Curtis recommends using ISO100 FSC- 1000A CURTIS-LUBEPLUS. 1. For proper lubrication the compressor shall not be operated below the minimum or above the maximum R.P.M.
To help prevent catastrophic damage, FS Curtis provides an option for a Low Oil Guard, which shuts the unit down when the oil level has dropped below the low oil mark on the sight glass or dipstick, see Fig (12) for proper oil level. FS Curtis’s low oil guard utilizes a magnetic float switch CAUTION! A low oil guard is not a substitution for proper maintenance.
CA / CT SERIES CAP600 Page 24 of 30 REV D July 2013 BELT TENSION CAUTION: Over tightening the v-belt(s) will result in overloading of the motor, and/or belt and pulley failure. A loose belt will result in an unstable speed, premature belt wear, “throwing” belts and a high amp draw.
Page 26
CA / CT SERIES CAP600 Page 25 of 30 REV D July 2013 Gage Average Model Deflection Tension Minimum Maximum 555VT6 1/4" 13lb 11lb 14lb 555VT8 1/4" 10lb 12lb 775VT8 1/4" 10lb 12lb 1075HT12 1/4" 10lb CT Gas 13-14 3/8" 20lb 18lb 23lb...
CA / CT SERIES CAP600 Page 26 of 30 REV D July 2013 Maintenance Parts and Rebuild Kits To order replacement parts for routine maintenance, please contact your local distributor. CHALLENGE AIR REBUILD KITS Kit Number Kit Number Kit Number Kit Number Oil (12 quart case) VO411-3...
CA / CT SERIES CAP600 Page 27 of 30 REV D July 2013 Troubleshooting Problem Cause Remedy Power not on Check breaker and / or disconnect Fuse blown Replace the fuse or disconnect Low voltage supplied Contact distributor Unit won’t start Worn pressure switch contacts Replace Starter overload tripped...
Page 29
CA / CT SERIES CAP600 Page 28 of 30 REV D July 2013 Problem Cause Remedy Manual drain not fully closed Close the drain cock (standard model) Automatic drain not fully closed (if Clean or replace automatic drain applicable) Clogged air filter / intake Replace the filter Leaks in air distribution system Check fittings, bushings and...
CA / CT SERIES CAP600 Page 29 of 30 REV D July 2013 Maintenance Checklist NOTE: Please keep a record of changes and have this list available when calling technical service. OIL CHANGED Initials Date Changed Oil Low? (y/n) Initials Date Changed Oil Low? (y/n) BELT TENSIONING Initials...
Page 31
CA / CT SERIES CAP600 Page 30 of 30 REV D July 2013 Maintenance Checklist NOTE: Please keep a record of changes and have this list available when calling technical service. Valve Inspected Initials Date Checked Initials Date Checked Air Leak Checks Initials Date Checked Comments...
Page 32
Curtis-Toledo, Inc. 1905 Kienlen Avenue | St. Louis, Missouri 63133 314-383-1300 or 800-925-5431 www.fscurtis.com | info@fscurtis.com...