Installation Instructions

1. THIS PRODUCT MUST BE EARTHED. Use only a flexible
cable or cord provided with a green or green and yel
low core which must be connected to the protective
earthing terminal of the detachable Neutrik 'powerCON'
type NEC3FCA connector (Tannoy part number 3461 0919)
as supplied with the equipment. The other end of the green
or green and yellow conductor must be connected to the
earthing pin of a suitable mains plug or the earthing terminal
of the installation. The cord must be of maximum length 7.5
meters, rated SJ, SJT, or SJE, 10A minimum and be
marked VW-1.
2. The electrical power connection to this product is only to
be made via a detachable Neutrik 'powerCON' type
NEC3FCA connector (Tannoy part number 3461 0919) as
supplied with the equipment. Wiring to this connector
must be made by suitably qualified personnel and must
comply with all local requirements.
3. Do not install this equipment in an enclosed space. Do not
limit free ventilation and movement of air around the back
panel. Ensure that there is at least 100 mm (4") of space
around all sides of the product for ventilation. Only use
attachments and accessories approved or specified by Tannoy.
Installation Instructions
FOR CUSTOMERS IN EUROPE
This product complies with both the LVD (electrical safety)
73/23/EEC and EMC (electromagnetic compatibility) 89/336/
EEC directives issues by the commission of the European
community. Compliance with these directives implies
conformity with the following European standards:
EN60065 Product safety
EN55103-1 EMC emissions
EN55103-2 EMC immunity
This product is intended for the following electromagnetic
environments: E2; E3 & E4. Environment E1 (domestic) is
specifically excluded.
FOR CUSTOMERS IN THE USA & CANADA
This product has been tested for electrical safety and
complies with:
UL60065 7th edition
CA/CSA C22.2 No.60065-03 EMC
This equipment has been designed to comply with the limits for
a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a
commercial environment.
Industry Canada Class A emission compliance statement:
This Class B digital apparatus complies with Canadian ICES-003.
Avis de conformite' a' la re'glementation d'Industrie Canada, cet
appareil nume'rique de classe A est conforme a' la norme ICES-
003.