NEC Express5800 Series User Manual page 31

Esmpro agent
Hide thumbs Also See for Express5800 Series:
Table of Contents

Advertisement

11.
Using IDE Mirroring Controller (Promise Fasttrak100/100LP)
NEC ESMPRO manages IDE Mirroring Controller (Promise Fasttrak100/100LP) in a
similar way as it manages SCSI and IDE devices except for the following points:
– DataViewer
All hard disk drives connected with disk mirroring controller are displayed on data
viewer as one logical disk drive instead of displaying each hard disk drive. Also, disk
mirroring controller is not displayed on DataViewer as "Disk Array". It is displayed
as "SCSI Controller".
– Pre-Failure function of hard disk drive
The pre-failure function doesn't make any check on hard disk drives connected with
disk mirroring controller.
12.
Application log registered when system starting
About the event of Perflib
When system starting, Perflib log is registered to the application log.
The detailed information about an event log described on Microsoft Product Support
Services. Please check the contents.
[INFO] Events for Performance Monitor Extensions
http://support.microsoft.com/default.aspx?scid=kb;en-us;226494
Application Log Events Generated When You Start Performance Counter Query
http://support.microsoft.com/default.aspx?scid=kb;EN-US;296187
Event ID 2003 Warning Message Logged When Loading Performance Counters
http://support.microsoft.com/default.aspx?scid=kb;EN-US;267831
13.
Coexistence with the Oracle products
The installation of the Oracle products may change Startup Type of SNMP Service into
"Manual". If so, return the setting to "Automatic" and set up correctly according to the
description of the Oracle product.
14.
About "NEC ESMPRO Agent ESMDiskArray"
"NEC ESMPRO Agent ESMDiskArray" is installed also in the system in which a disk
array controller does not exist, and adds [NEC ESMPRO Agent ESMDiskArray] to the
[Start] menu.
(Monitoring is not performed while the status of service "ESMDiskArray" is "Started.")
In this case, please do not use the "NEC ESMPRO Agent ESMDiskArray Console" which
performs of monitoring interval and maintenance of "NEC ESMPRO Agent
ESMDiskArray".
(When click a [Start] menu, [NEC ESMPRO Agent ESMDiskArray], and a [Console], the
console displays the message which shows that the disk array controller for a monitor
does not exist.)
Note 27