8800 series all-ceramic macerator toilet (20 pages)
Summary of Contents for SeaLand VacuFlush 3000 Series
Page 1
3100 Series 3400 Series 3000 Series 3300 Series IMPORTANT NOTICE VacuFlush sanitation systems must be installed according to Dometic’s recommended procedures. Do not attempt installation without first contacting a VacuFlush Certified Dealer, your nearest VacuFlush Parts Distributor, or Dometic. WARNING WARNING...
ToILeT moDeL IDeNTIFICATIoN The model identification label is located on the inside wall of the toilet under DOMETIC CORPORATION the tank access cover. It will show the model number and serial number. P.O. BOX 38, 13128 STATE RT 226 (800) 321-9886 BIG PRAIRIE, OH 44611 USA MODEL NO.
opeRATING INSTRuCTIoNS 1. Adding more Water To Toilet bowl RemoTe FLuSH HANDLe STATuS Raise flush handle or press “Add Water” switch until desired SWITCH pANeL water level is attained. To prevent toilet overflow, the control ADD WATER TO BOWL module limits the amount of water that can be added. 2.
FLuSH opeRATIoN TImING CHART Flush and Forget Cycle Time ® Water valve Low Refill Normal Refill High Refill Flush valve Begin Opening for 0.1 sec. Wait for 0.1 sec. Continue Opening Held Open Closing Time Flush Cycle In Seconds Additional “Add Water” Time Allowance “Add Water”...
(2 ea. per kit) oRDeRING pARTS Dometic is ready to assist you in the event service is required. Before calling, please have the following information available. Your cooperation in having this information ready is appreciated and allows us to better meet your needs.
SANITATIoN SYSTem CompoNeNTS Vacuum Toilet: VacuFlush all-ceramic vacuum toilets with vacuum Toilets technology operate differently compared Flush and Forget ® to other toilets. The vacuum system uses a small amount of water (a little more than a pint or .5 liter) per flush in addition to a simple vacuum.
SANITATIoN SYSTem CompoNeNTS (cont’d) TankWatch Level Indicator (marine option only): ® The TankWatch unit utilizes micro-float switches which TankWatch activate an indicator panel. The micro-float switches are panel and installed in the top of the holding tank. The adjustable probes probe assemblies are flexible polybutylene tubing and are designed to flex when tank contents move.
Sewage from any source should not be discharged directly into our waters. If you are interested in learning more about this issue, please contact Dometic at the phone number or address listed on the back page of this manual.
FLuSH meCHANISm CompoNeNTS 2. Remove access cover. 3. Lift china toilet . To a c c e s s straight up and set it Lift up control module. Dis- base assembly connect power cable and down close to front of c o m p o n e n t s , vacuum control cable from floor flange/adapter...
mANuAL FLuSH opeRATIoN In the event of an electrical failure, the flush ball can be manually operated to clear the bowl. We recommend using a long-neck screwdriver or 7/16-in. socket for the operation shown below. NEVER PRY OPEN THE FLUSH BALL FROM INSIDE THE TOILET BOWL.
TRoubLeSHooTING A volt/ohmmeter (VOM) and the appropriate Toilet Wiring Diagram may be required for this section. Caution: Portions of this section will require that power be applied to the toilet. Keep hands away from the flush ball, motor drive arm and rotor shaft to prevent personal injury during testing and troubleshooting. The control module uses a microprocessor to provide all the automatic and timing functions.
TRoubLeSHooTING (cont’d) eRRoR CoDe CoRReCTIve pRoCeDuReS Condition Corrective Action Mode Switch in SERVICE position. Return Mode Switch to NORMAL position. Valve Open Limit Switch problem. With the flush valve fully open, check the “VALVE OPEN” status light. If the light is off, then the Valve Open Limit Switch is out of alignment or defective, or related wiring is defective.
Page 13
TRoubLeSHooTING (cont’d) SYmpTom 3. Flush valve will not close. Condition/Procedure Corrective Action • Return switch to the “Normal” position. Mode Switch is in SERVICE position: • Reset the control circuit by putting the Mode Switch in the SERVICE Foreign object prevents the flush position temporarily, then returning to the NORMAL position.
Page 14
TRoubLeSHooTING (cont’d) SYmpTom 8. Water will not stay in bowl and system loses vacuum. Condition/Procedure Corrective Action Put Mode Switch in “Service” • Clean underside of flush valve ball seal of dirt and debris. position: Worn or damaged flush valve ball •...
Page 19
mARINe WIRING DIAGRAmS (cont’d) MARINE VACUFLUSH STATUS PANEL / TANKWATCH OPTION vACuFLuSH STATuS pANeL opTIoN IMPORTANT: ORANGE WIRE ON PIN 15 OF CONTROL MODULE MUST BE CONNECTED TO THE “A” TERMINAL OF THE VACUUM SWITCH REGARDLESS OF WHICH VACUUM SOURCE IS USED.
Page 20
mARINe WIRING DIAGRAmS (cont’d) VACUUM GENERATOR/VACUUM TANK AND PUMP OPTION m-SeRIeS vACuum pump AC CIRCuIT opTIoN...
mARINe WIRING DIAGRAmS (cont’d) m-SeRIeS vACuum pump DC CIRCuIT opTIoN DImeNSIoNS models 3006, 3106* models 3309, 3348, 3409*, 3448* 300 and 3400 series toilets operate with wall-mounted flush switch, and do not include flush handle on toilet. models 3009, 3048, 3109*, 3148* China toilet dimensions may vary ±3/8-inch (0mm).
Center near you, please call from 8:00 a.m. to 5:00 p.m. (ET) parts needs. They carry a complete inventory for the SeaLand Monday through Friday. You may also write us at Dometic product line. Corp., P.O. Box 38, Big Prairie Ohio 446.
(1) year from the date of purchase. If this Dometic product is placed in commercial or business use, it will be warranted, to the original purchaser only, to be free of defects in material and workmanship for a period of ninety (90) days from the date of purchase.
Need help?
Do you have a question about the VacuFlush 3000 Series and is the answer not in the manual?
Questions and answers