Option #1 - The power cord can be lead from behind the trim and
along the wall to an outlet near the fireplace.
Option #2 - A new outlet can be installed inside the new frame
construction.
Dimplex Mantel Surround Kit or Custom Made Mantel
Surround
1. Select a suitable location that is not susceptible to moisture and is
away from drapes, furniture and high traffic.
2. Place the fireplace in the desired location to see how it will look in
the room.
3. For ease of electrical hook up you may wish to locate the fireplace
near an existing outlet (refer to NOTE 1).
4. Store the fireplace in a safe dry and dust free location.
5. Assemble the mantel surround kit (refer to the mantel assembly
instructions) or construct the custom surround with an opening of
30 3/4 inch (78.1 cm) wide X 25 3/4 inch (65.4 cm) high X 11 3/4
inch (29.8 cm) deep (Figure 3).
WARNING: Do not attempt to wire your own new outlets or circuits.
To reduce the risk of fire, electric shock or injury to persons, always
use a licensed electrician.

Fireplace Insert Installation

1. Make sure the unit's Main ON/OFF switch is switched OFF (refer to
operating instruction section).
2. Plug the unit into a 15 Amp/120 Volt outlet. If the cord does not
reach, you may use an extension cord rated for a minimum of 1875
Watts.
3. Push the fireplace into the opening being careful not to damage the
base of the mantel or cabinet so that the fireplace is flush with the
mantel or cabinet.
4. Level the unit with shims if necessary (not provided).
5. Install the trim onto the fireplace (refer to trim installation
instructions).