Utilisation of the dispersion characteristics (110 70 ) of the loudspeaker allows the i7 Contour to be used in highly reverberant environments, by directing the sound into the desired space whilst minimising reflections from adjacent walls or ceilings.
CABLE RUN C.S.A. OF EACH CABLE % POWER LOSS % POWER LOSS CONDUCTOR (mm) RESI STANCE INTO 8 LOAD INTO 4 LOAD 0.14 0.09 0.06 0.73 0.35 0.22 0.14 0.69 17.0 0.43 11.0 0.29 1.38 17.0 35.0 0.86 11.0 22.0 0.58 14.0 4.
7. Equalisation The i7 Contour loudspeaker is designed to need no equalisation or correction to overcome system limitations. As a result, it will only need equalisation to compensate for difficult acoustic environments.
9. Hardware The i7 Contour can be wall or ceiling mounted using the MB7 (optional) bracket (fig 1.) which is designed to rotate about its axis. The MB7 is supplied with M6 bolts for fixing to the loudspeaker. After fixing the bracket to the wall or ceiling, position the cabinet at the required angle as shown (fig.
Tannoy operates a policy of continuous research and development. The introduction of new materials or manufacturing methods will always equal or exceed the published specifications which Tannoy reserve the right to alter without prior notice. Please verify the latest specifications when dealing with critical applications.
12. Troubleshooting Guide Symptom Possible Cause Action No Output From Speakers Broken Speaker Cables(s) Check the electrical continuity of the loudspeaker cables, and replace if necessary. Amplifier Check the gain controls on the amplifier are turned up. Be sure the amplifier is receiving an input signal (check the “signal”...
Claims will not be considered if the serial number has been altered or removed. Work under warranty should only be carried out by a Tannoy Professional dealer or service agent. This warranty in no way affects your statutory rights. For further information please contact your dealer or distributor in your country.
15. Declaration of Conformity The following apparatus is/are manufactured in the United Kingdom by Tannoy Ltd of Rosehall Industrial estate, Coatbridge, Scotland, ML5 4TF and conform(s) to the protection requirements of the European Electromagnetic Compatibility Standards and Directives relevant to Domestic Electrical Equipment. The apparatus is designed and...
Page 14
Internet:http://www.tannoy.com TGI/Tannoy, 300 Gage Avenue, Kitchener, Ontario, CANADA, N2M 2C8 Telephone: (519) 745 1158 Fax: (519) 745 2364 Tannoy Nederland BV, Anthonetta Kuijistratt 19, 3066GS, Rotterdam THE NETHERLANDS Telephone: (015) 2124034 Fax: (015) 2125213 Tannoy is a member of the Group of Companies Issue 1 Part No.
Need help?
Do you have a question about the i7 Contour and is the answer not in the manual?
Questions and answers