Able to deliver consistent performance under a wide range of adverse conditions the i6 AW is suited to applications indoors or out, whether it be a theme bar or theme park. Available in dark grey or white the i6 AW will effectively blend into most backgrounds.
CABLE RUN C.S.A. OF EACH CONDUCTOR (mm) 4. Polarity Checking It is most important to check the polarity of the wiring. A simple method of doing this without a pulse based polarity checker for LF units is as follows: Connect two wires to the +ve and -ve terminals of a PP3 battery.
6. Power Selection (i6T AW) Determine the maximum power in watts needed at each speaker location. The i6 AW transformer can be tapped at 30w, 15w, 7.5w, & 3.75w via the rotary switch located on the metal plate at rear of the loudspeaker. When the relevant tappings have been selected add the individual wattages required at all speakers and select an amplifier with a rating equal to or exceeding the total wattage required.
9. Hardware The i6AW can be wall or ceiling mounted using the MB6 (optional) bracket (fig 1.) which is designed to offer the maximum flexibility in selecting the desired angles. The MB6 is supplied with M8 bolts for fixing to the loudspeaker (fig1.& 2). After fixing the bracket to the wall or ceiling remove the plastic plugs from the top and bottom of the loudspeaker.
12. Troubleshooting Guide Symptom No Output From Speakers Intermittent Output Poor Low Frequency Output Irregular sounds such as buzzing and humming emanating from the loudspeaker Possible Cause Broken Speaker Cables(s) Amplifier Poor Connection “Out of phase” connection Poor system grounding Faulty electronic device in the signal chain Action...
7300 0684 8000 0920 14. Warranty No maintenance of the i6 AW loudspeaker is necessary. All Tannoy professional loudspeaker products are covered by a 5 year warranty from the date of manufacture subject to the absence of misuse, overload or accidental damage.
Declaration of Conformity The following apparatus is/are manufactured in the United Kingdom by Tannoy Ltd of Rosehall Industrial estate, Coatbridge, Scotland, ML5 4TF and conform(s) to the protection requirements of the European Electromagnetic Compatibility Standards and Directives relevant to Domestic Electrical Equipment. The apparatus is designed and constructed such that electromagnetic disturbances generated do not exceed levels allowing radio and telecommunications equipment and other apparatus to operate as intended, and, the apparatus has an adequate level of intrinsic immunity...