Heat & Glo SOLARIS36-ST Owner's Manual page 14

Table of Contents

Advertisement

L.E.D Replacement
Frequency: As needed
By: Qualifi ed Service Technician
Tools needed: Protective gloves, replacement LED Strips,
3/8 in nut driver.
• Remove four panels from decorative front.
• Unplug LED wire assembly from control box.
• Remove large decorative front panel from fi replace.
• Loosen three 3/8 in. nuts that attach the LED strip to the
decorative panel.
• Unplug wire from LED strip.
• Plug the wire into the new LED strip.
• Place LED strip onto the three threaded studs on the
decorative panel.
• Tighten the three 3/8 in. nuts to secure the LED strips
in place.
• Replace the large decorative panel on the fi replace.
• Replace the four panels on the decorative front.
Gasket Seal and Glass Assembly Inspection
Frequency: Annually
By: Qualifi ed Service Technician
Tools needed: Protective gloves, drop cloth and a stable
work surface.
• Inspect gasket seal and its condition.
• Inspect fi xed glass assembly for scratches and nicks that
can lead to breakage when exposed to heat.
• Confi rm there is no damage to glass or glass frame.
Replace as necessary.
• Verify that fi xed glass assembly is properly retained and
attachment components are intact and not damaged.
Replace as necessary.
Firebox
Frequency: Annually
By: Qualifi ed Service Technician
Tools needed: Protective gloves, sandpaper, steel wool,
cloths, mineral spirits, primer and touch-up paint.
• Inspect for paint condition, warped surfaces, corrosion
or perforation. Sand and repaint as necessary.
• Replace fi replace if fi rebox has been perforated.
Control Compartment and Firebox Top
Frequency: Annually
By: Qualifi ed Service Technician
Tools needed: Protective gloves, vacuum cleaner, dust
cloths
• Vacuum and wipe out dust, cobwebs, debris or pet hair.
Use caution when cleaning these areas. Screw tips that
14
• Remove all foreign objects.
Burner Ignition and Operation
Frequency: Annually
By: Qualifi ed Service Technician
Tools needed: Protective gloves, vacuum cleaner, whisk
broom, fl ashlight, voltmeter, indexed drill bit set, and a
manometer.
• Verify burner is properly secured and aligned with pilot
• Check for smooth lighting. Verify that there is no ignition
• Inspect for lifting or other fl ame problems.
• Verify air shutter setting is correct. See Section 14 for
• Inspect orifi ce for soot, dirt and corrosion. Verify orifi ce
• Verify manifold and inlet pressures. Adjust regulator as
• Inspect pilot fl ame pattern and strength. See Figure 3.1
• Inspect IPI fl ame sensing rod for soot, corrosion and
• Verify that there is not a short in fl ame sense circuit
Figure 3.1 IPI Pilot Flame Patterns
Heat & Glo • Solaris • 2179-900 Rev. E • 4/11
have penetrated the sheet metal are sharp and should
be avoided.
or igniter.
delay.
required air shutter setting. Verify air shutter is clear of
dust and debris.
size is correct. See Service Parts List for proper orifi ce
sizing.
required.
for proper pilot fl ame pattern. Clean or replace orifi ce
spud as necessary.
deterioration. Clean with emery cloth or replace as
required.
by checking continuity between pilot hood and fl ame
sensing rod. Replace pilot as necessary.