4.
Open the globe valve fully to per-
mit air to escape and prevent air
pressure build up in the air tank
during the break-in period.
5.
Move the On/Auto/Off lever to
"On/Auto" position. The compres-
sor will start.
6.
Run the compressor for 20 min-
utes. Make sure the globe valve
is open and there is minimal air
pressure build-up in tank.
7.
Check all air line fittings and con-
nections/piping for air leaks by
applying a soap solution. Correct
if necessary. NOTE: Minor leaks
can cause the air compressor to
overwork, resulting in premature
breakdown or inadequate perfor-
mance.
8.
Check for excessive vibration.
Readjust or shim air compressor
feet, if necessary.
9.
After 20 minutes, close the globe
valve. The air receiver will fill to
"cut-out" pressure and the motor
will stop.
Before Each Start-Up:
1.
Place On/Auto/Off lever to "Off".
2.
Close the globe valve.
3.
Attach hose and accessories.
grasp air hose in hand when
installing or disconnecting to
prevent hose whip.
use damaged or worn accessories.
NOTE: A regulator MUST be installed
when using accessories rated at less
than 175 psi.
NOTE: The hose or accessory will
require a quick connect plug if the air
outlet is equipped with a quick con-
nect socket.
Risk of unsafe
operation. Firmly
Risk of unsafe
operation. Do not
pressure causes a hazardous risk of
bursting. Check the manufacturer's
maximum pressure rating for air
tools and accessories. The regulator
outlet pressure must never exceed
the maximum pressure rating.
Compressed air from the unit may
contain water condensation and
oil mist. Do not spray unfiltered air
at an item that could be damaged
by moisture. Some air tools and
accessories may require filtered
air. Read the instructions for the air
tools and accessories.
How to Start
1.
Turn the On/Auto/Off lever to "On/
Auto" and allow tank pressure to
build. Motor will stop when tank
pressure reaches "cut-out" pres-
sure.
2.
When the tank pressure reaches
"cut-out" pressure open the globe
valve.
IMPORTANT: When using regula-
tor and other accessories refer to the
manufacturers instructions.
is noticed, stop the compressor
immediately and have it checked by
a trained service technician.
The compressor is ready for use.
15-ENG
15-ENG
Risk of Bursting.
Too much air
Risk of unsafe

operation.

:
If any unusual
noise or vibration
N004035

Hide quick links: