OmniSwitch 6850 Series Chassis and Hardware Components
Monitoring the Chassis
OmniSwitch 6850 Series switches can be monitored and managed via the console port using Command
Line Interface (CLI) commands. The switches can also be monitored and managed via the Ethernet using
CLI commands, WebView, SNMP, and OmniVista.
The section below provides some examples of useful hardware-related monitoring CLI commands. Refer
to the OmniSwitch CLI Reference Guide for detailed information on all management and monitoring
commands used with the OmniSwitch 6850 Series switch.
Checking the Overall Chassis Status
To check the overall status of a chassis, including the chassis type, and current administrative and opera-
tional status, use the
-> show chassis
Chassis 1
Model Name:
Description:
Part Number:
Hardware Revision:
Serial Number:
Manufacture Date:
Admin Status:
Operational Status:
Number Of Resets:
For a complete list of output definitions for this command, refer to the OmniSwitch CLI Reference Guide.
Checking the Temperature Status
To check chassis temperature status, including the current temperature and configured threshold values,
use the
show temperature
-> show temperature
Temperature for chassis 1
Hardware Board Temperature (deg C)
Hardware Cpu Temperature (deg C)
Temperature Upper Threshold Range (deg C)
Temperature Upper Threshold (deg C)
Temperature Range
Temperature Danger Threshold (deg C)
For a complete list of output definitions for this command, refer to the OmniSwitch CLI Reference Guide.
OmniSwitch 6850 Series Hardware Users Guide
show chassis
command. For example:
OS6850-48,
10/100/1000,
902274-10,
005,
439L0024,
SEP 22 2005,
POWER ON,
UP,
1
command. For example:
August 2007
Monitoring the Chassis
= 38,
= N/A,
= 30 to 72,
= 57,
= UNDER THRESHOLD,
= 72