Recovering From Pass-Through Mode (Duplicate Slot Numbers) - Alcatel-Lucent OmniSwitch 6850 Series Hardware User's Manual

Hide thumbs Also See for OmniSwitch 6850 Series:
Table of Contents

Advertisement

Managing OmniSwitch 6850 Series Stacks
To avoid a pass-through condition following a reboot, make sure that all saved slot values for the stack are
unique. Use the
stack set slot
slot 3 from 2 to 3:
-> stack set slot 3 saved-slot 2
Use the
show stack topology
-> show stack topology
NI
Role
----+-----------+--------+------+-------+-------+-------+-------+-------+-------
1 PRIMARY
2 SECONDARY
3 IDLE

Recovering from Pass-Through Mode (Duplicate Slot Numbers)

The first step in recovering from pass-through is to determine which modules are currently operating in
pass-through, as well as the reason for the pass-through state. To view this information, use the
show stack topology command. For example:
-> show stack topology
NI
Role
----+-----------+--------+------+-------+-------+-------+-------+-------+-------
1 PRIMARY
2 SECONDARY
1001 PASS-THRU
Switches operating in pass-through mode are given distinct slot numbers. These slot numbers are not
related to their position in the stack. Instead, they are assigned the prefix "100," followed by the numeri-
cal order in which they were forced into pass-through (1001–1008).
Note. For pass-through elements 1001 through 1008, the slot indicator LED on the chassis front panel
blinks 1 through 8, respectively. For example, if a module enters pass-through and has the slot number
1004, the LED for the module blinks the number 4. For more information on the slot indicator LED, refer
to
"Status LEDs" on page
In the example above, the switch with the NI (i.e., slot) number 1001 is operating in pass-through. Note
that the role assignment is PASS-THRU; also, the state displays DUP-SLOT, or duplicate slot number.
This can be further verified by looking down the saved slot column in the table. Note that slot 2, operating
in the secondary management role, has a saved slot value of 2. Slot 1001, operating in pass-through, also
has a saved slot value of 2.
OmniSwitch 6850 Series Hardware Users Guide
command. For example, change the saved slot value for the idle switch in
command to verify the change:
State
Saved
Link A
Slot
State
RUNNING
1
UP
RUNNING
2
UP
RUNNING
3
UP
State
Saved
Link A
Slot
State
RUNNING
1
UP
RUNNING
2
UP
DUP-SLOT
2
UP
2-54.
August 2007
Link A
Link A
Remote
Remote
Link B
NI
Port
State
3
StackA
UP
1
StackB
UP
1
StackA
UP
Link A
Link A
Remote
Remote
Link B
NI
Port
State
1001
StackA
UP
1
StackB
UP
1
StackA
UP
Roles Within the Stack
Link B
Link B
Remote
Remote
NI
Port
2
StackA
3
StackB
2
StackB
Link B
Link B
Remote
Remote
NI
Port
2
StackA
1001
StackB
2
StackB
page 4-13