Clean the chimney using a brush the same size and
shape as the flue liner. Flexible fiberglass rods are used
to run the brush up and down the liner, causing any
deposits to fall to the bottom of the chimney where they
can be removed through the clean-out door.
Clean the chimney connector by disconnecting the sec-
tions, taking them outside, and removing any deposits
with a stiff wire brush. Reinstall the connector sections
after cleaning, being sure to secure the joints between
individual sections with sheet metal screws.
If you cannot inspect or clean the chimney yourself,
contact your local Vermont Castings dealer or a profes-
sional chimney sweep.

Maintenance Schedule

The Stove

Daily:
Clear any ash build-up from around the air holes and
combustion flow path in the lower fireback.
Ashes should be removed before they reach the top
of the ash pan. Check accumulation at least once a
day.
Keep the area around the stove clear of any com-
bustible materials such as wood, furniture or cloth-
ing.
Two MoNThS:
Check door handle to be sure it is working properly.
Gasketing becomes compressed after a period of
time. Adjust handle tightness if necessary.
Check leg bolts and heat shield screws; tighten if
necessary.
aNNUal SpRiNg cleaNiNg:
Check gasketing for wear, and replace if necessary.
Remove ashes from the ash pan and replace with a
moisture absorbing material (such as kitty litter) to
keep the interior of the stove dry.
Clean the dust from the inner sides of bottom, rear or
pipe heat shields if your stove is equipped with them.
Clean surfaces are better heat reflectors than dirty
surfaces.
Touch up the black paint.
Inspect for and remove ash build-up behind the com-
bustion package. This should be done in conjunc-
tion with annual cleaning of the chimney connector.
Inspect the passage behind the combustion package
(a mirror will be helpful) and vacuum away ash using
a flexible vacuum hose inserted the passage. (Fig.
44)
30005220
Defiant
1975 Non-Catalytic / Catalytic Woodburning Stove
®

The chimney connector

Two weekS:
Inspect the chimney connector and chimney. Clean if
necessary.
Two MoNThS:
Inspect the chimney and chimney connector. Pay
particular attention to the horizontal runs of chimney
connector, and the elbows. Clean the system if nec-
essary.
aNNUal SpRiNg cleaNiNg:
Disassemble the chimney connector and take it
outdoors for inspection and cleaning. Replace weak
sections of connector.
Inspect the chimney for signs of deterioration. Re-
pairs to a masonry chimney should be made by a
professional mason. Replace damaged sections of
prefabricated chimney. Your local Vermont Castings
dealer or a chimney sweep can help determine when
replacement is necessary.
Thoroughly clean the chimney.
Remove these components
Fig. 47 Inspect and clean out ash accumulation behind the
combustion system.
Clean
out any
ash build
ST1162
ST1162
ash clean out
up
33