Vermont Castings Defiant 1975 Installation And Operating Manual page 17

Non-catalytic / catalytic woodburning stove
Table of Contents

Advertisement

48"
(1220 mm)
48"
(1220 mm)
Fig. 16 Parallel installation, vertical chimney connector, two
wall shields. Reduced clearances for both rear and side walls.
Wall shields may meet at corner if desired. Shielding for con-
nector is centered behind connector.
48"
(1220 mm)
48"
(1220 mm)
Fig. 17 Parallel installation with rear wall pass-through, two
wall shields. Reduced clearances to both rear and side walls.
Wall shields may meet at corner if desired. Wall pass-through
must comply with codes.
ST498
Defiant
Refer to "Special Installations."
Wall shield B
11/00
30005220
48"
(1220 mm)
48"
(1220 mm)
ST497
ST497
Defiant
wall shield A
11/00
48"
(1220 mm)
ST498
Defiant
1975 Non-Catalytic / Catalytic Woodburning Stove
®
48"
(1220 mm)
Fig. 18 Corner installation, vertical chimney connector, two
wall shields. Reduced side clearances. Wall shield MUST
meet at corner.
48"
48"
(1220 mm)
(1220 mm)
ST499
Defiant
Wall Shield C
11/00
48"
(1220 mm)
ST499
17