ADJUSTING THE THERMOSTAT
Factory temperature pre-set is 200˚F.
To reset the thermostat to 200°,
turn the indicator two notches to
the right of vertical.
■ ■
Adjust the thermostat slowly,
turning the dial clockwise
to increase temperature or
counter clockwise to decrease temperature, then
activate faucet handle for 20 seconds to bring in
fresh water to be heated at the new setting. Allow
5-7 minutes for water to reach new temperature.
SEASONAL STORAGE/DRAINAGE
Anytime the instant hot water dispenser is not used
for extended periods of time, unplug and drain unit.
If it is below freezing you will need to unplug the
unit and drain it.
■ ■
Disconnect power from unit.
■ ■
Push hot water dispenser faucet lever
and allow water to flow until it is cool.
■ ■
Shut the cold water supply off at the valve.
■ ■
If drain screw equipped, locate and
remove from bottom center of water tank
and drain the water into empty pail.
■ ■
Empty the tank and then reinstall drain
screw onto the bottom of tank, turning
until snug. Do NOT over tighten.
■ ■
If drain screw not equipped, disconnect
water supply tubes, remove tank and
invert to drain. Remount tank.
■ ■
Remove and drain filter cartridge
(if installed). Reinstall.
■ ■
To place back in working order, fill tank
with water and re-connect the plug.
CLEANING THE FAUCET AND TANK
■ ■
Only use mild cleaners to clean the faucet
and plastic components.
■ ■
Cleaners with acids, abrasives, alkaline or
organic solvents will result in deterioration of
the plastic components and void the warranty.
14

CARE AND USE

Electric Shock Hazard: To prevent electrical shock, disconnect power before
servicing unit. Use only a properly grounded and polarized electric outlet.
approx. 200°
Scalding Hazard: Do not allow
water to boil. May result in
severe burns.
PROPERTY DAMAGE
■ ■
Regularly inspect the unit for any signs of
leakage. If there are signs of water damage,
immediately remove the unit from service.
■ ■
To avoid water damage from leakage,
replace all cut, loose or split tubing.
■ ■
A drain pan, plumbed to an appropriate
drain or outfitted with a leak detector,
should be used in those applications where
any leakage could cause property damage.
FILTER GUIDE AND REPLACEMENT
(Filtration available as an option)
Replace filter cartridge when there is an obvious
decrease in water flow to the faucet or if there is an
objectionable taste or odor to the water.
When the inlet and outlet ports have been closed
and the filter's internal pressure has been relieved,
water (about 2 oz) will discharge from vent line.
If the new filter cartridge cannot be inserted,
insert the old one and turn until it stops, remove it
and then retry the new cartridge.
Carbon filters should be replaced within 12 months.
Filter replacement instructions:
■ ■
Replace with an InSinkErator
■ ■
Place pan or dish towel under the filter to
catch water drainage during change.
■ ■
Slowly turn the cartridge counter-clockwise
completely until it stops (1/4 turn).
■ ■
Pull cartridge straight down and discard.
■ ■
Insert new cartridge into filter head.
■ ■
Top surface of cartridge will become flush
with the bottom of the filter head when
fully engaged.
■ ■
Turn the cartridge clockwise until it stops
(1/4 turn).
■ ■
Align the in/out arrow on the head and
bracket assembly to the in/out arrow on
the cartridge.
■ ■
Open faucet to expel trapped air.
■ ■
Run water for 3 minutes before usage.
®