PROBLEM
A steaming hot water tap, like any water heater, has a limited
life and will eventually fail. To avoid possible property damage,
Water and steam spits
forcefully from spout
this steaming hot water tap should be regularly examined for
without turning on
leakage and replaced when necessary. A drain pan, plumbed to
the tap.
an appropriate drain or outfitted with a leak detector, should
be used in those applications where any leakage could cause
property damage.
Water is not hot
WARRANTY INFORMATION
Tap:
Series 1100, 2-year warranty
LED green light on
H990, 1-year warranty
front of tank does not
illuminate
Tank:
2-year warranty on stainless steel tank
Water is too hot
Covers all replacement parts and labour to correct
or not hot enough
defects in material or workmanship in the tap system,
excluding the replaceable filter cartridge, for the full
Water comes out the
vent instead of spout
warranty period from the date of installation in your
home. If warranty service is required during the warranty
Water is dripping
period, contact an authorized InSinkErator
®
service agent
from the spout/vent
to replace or repair the unit in your home at no cost to
intermittently
you. If your tap is replaced rather than repaired, the
warranty on the new unit shall be for the duration of the
remaining portion of the original tap warranty. Note:
Warranty is determined by unit serial number and/or date
Water is dripping
of installation. Purchase or installation receipt may be
from the spout/vent
constantly
required to verify warranty status. To find the location of
your nearest factory authorized service center, please see
Divided stream
attached service agent list.
FILTRATION ISSUES
The foregoing warranty does not apply to damage or
Water taste or odour
inoperation resulting from accident, alteration, misuse,
abuse, improper installation, installation not in
accordance with these instructions or local electrical
New filter doesn't fit
and/or plumbing codes. We do not assume any
responsibility for consequential damage. Install using
genuine InSinkErator manufactured components only. Use
The filter leaks
of non InSinkErator components will void your warranty.
No water flow or
low water flow
PN 43899
TROUBLESHOOTING
POSSIBLE CAUSE
WHAT TO DO
• Unit is boiling.
• Depress tap lever to release some water from
the tank.
May be normal during initial setup.
• Adjust water temperature using dial on tank front.
Remember that at higher altitudes, water boils
at lower temperatures. See Owner's Manual
• The unit may not be plugged in.
• Make sure the unit is connected to a properly
earth (grounded) electric outlet.
• The electric outlet is inoperative.
• Make sure the circuit breaker or fuses are
functioning properly.
• Check that the outlet is not switched off.
• The unit may not be plugged in.
• Make sure the circuit breaker or fuses are
functioning properly.
• Check that the outlet is not switched off.
• The electric outlet is inoperative.
• Thermostat is not adjusted to
• Adjust the thermostat slowly, then depress or twist tap
your needs.
handle for 20 secs. to bring in fresh water at the new setting.
Allow 5-7 minutes for water to reach new temperature.
• Outlet tube is blocked.
• Check that outlet tube is not kinked, twisted or pinched.
• Unscrew spout end piece and clean out any debris.
• The expansion chamber isn't
• Unplug the unit. If the dripping doesn't stop after a few
draining properly due to low
minutes, check the supply valve to ensure that it is fully
water pressure.
open and there are no obstructions in the water line
reducing the pressure below 172 kPa (1.7 bar; 25 psi).
i.e., a poorly mounted saddle valve, a clogged water filter,
or a partially opened shut-off valve.
• The spout is blocked.
• Unscrew spout end piece and clean out any debris.
• Debris in the water line may be
• Unscrew spout end piece and clean out any debris.
in the tap valve seat causing
• Depress or twist lever 7-10 times to flush tap & lines.
a slow water leak.
• Debris in the end piece.
• Unscrew spout end piece and clean out any debris.
If you are still experiencing trouble, visit www.insinkerator.com
• Filter water flow direction is wrong
• Review filter tube connection instructions.
• Filter needs to be flushed out
• Depress/twist tap and run until the water is cold.
• Life of filter has expired
• If no change, replace filter cartridge.
• Head & bracket not fully rotated
• Take out the new filter, put in old filter.
• Remove, inspect, reinstall filter cartridge.
• Filter O-ring breach
• Head & bracket not fully rotated
• Test unit by reinstalling old filter and rotating
• Filter O-ring breach
to full stop. Check for leaks.
• Life of filter has expired
• Replace filter cartridge.
HC1100
GN1100
H990
Steaming
Hot Water
Tap
Filtered 98°C
water on tap
Quick Installation Guide
What You Should Know
Before Beginning
This is a quick reference guide. Please refer
to the complete Installation, Care & Use Manual
®
for specifics including warnings, cautions and
dangers. If after reading the troubleshooting
section, you still have questions about parts,
installation or warranty, please visit
www.insinkerator.com
Please have the model and serial number of your
tank and tap available when calling. Visit
www.insinkerator.com for assistance on many
common questions.
Starting the Installation Process
• A continuous electrical power source (not controlled by
a wall switch) is required to power the unit.
Guía de instalación rápida
• Ensure that there is sufficient space to fit the unit
under the sink and around existing plumbing.
Guide d'installation rapide
• For HC1100 tap installation, a 35mm–38mm hole is
Kurzanleitung
required; for the GN1100 and H990 tap, the hole
Snelle installatiegids
requirement is 32mm–38mm. Many installers choose
to use the existing "sprayer" hole.
Guia de instalação rápida
• Check to make sure that a cold water supply line is
within reach of the water inlet line.
Hurtig installationsvejledning
Guida di installazione rapida
BEFORE INSTALLING REPLACEMENT TAP
Personal Injury: Unplug the tank. Depress the tap
handle for about one minute so cold water can
flow through the unit. This cools the water for
safer removal of existing tank and tap. Remove
the drain plug on the tank bottom to empty all
remaining water.

Advertisement

loading

Summary of Contents for Emerson HC1100

  • Page 1 If your tap is replaced rather than repaired, the Steaming i.e., a poorly mounted saddle valve, a clogged water filter, • For HC1100 tap installation, a 35mm–38mm hole is Kurzanleitung warranty on the new unit shall be for the duration of the or a partially opened shut-off valve.
  • Page 2 See Installation, Care & Use Manual for important cautions, warnings and dangers To prevent damage or unit operating properly, the water pressure must be between 172 kPa - 862 kPa (1.7 bar - 8.6 bar; 25 psi - 125 psi) FILTRATION STANDARD ON HC1100 & GN1100 OPTIONAL ON H990...

This manual is also suitable for:

H990Gn1100