Construction Access Mode is used to allow access before the lock has been programmed, and for
testing purposes.
• Enabled by default.
• The lock will remain in Construction Access Mode until
the mode is cancelled as described below.
• No audits are captured while lock is in Construction
Access Mode.
Create the Master Construction Credential -
Locks with Card Readers
!
The fi rst card presented to a new lock automatically
becomes the Master Construction Credential!
1. Press and hold the Schlage button while presenting a
credential.
2. This credential becomes the Master Construction
Credential and is used to program construction access.
3. The Schlage button will blink green on the left and
right as confi rmation.
After you have created the Master Construction
Credential, you can then use that card to add construction
access mode user credentials.
The Master Construction Credential will not grant access. It is used only to add additional
credentials.

Add Construction Access Mode User Credentials - Locks with Card Readers

1. Present the Master Construction Credential to the lock. The Schlage button will light.
2. Present the user credential to be added within twenty (20) seconds. The user credential will be
added to the lock database.
3. Repeat for additional user credentials.
Credentials added using the Master Construction Credential will have normal 24/7 access.

Cancel Construction Access Mode

Do one of the following:
• Program the lock with the SUS. See the SUS User Guide for more information.
• Reset the lock to factory settings. See Reset To Factory Defaults on page 11 for more information.
!
When construction mode is cancelled, the Master Construction Credential and all other
credentials added using the Master Construction Credential will no longer function.

Locks with Keypads

In the factory default state, offl ine locks with keypads, with or without additional credentials, have a
default PIN of 13579 and "#", which can be used for installation, testing and construction access. To
test, enter default PIN. The Schlage button will blink and the lock will unlock.
The default PIN, 13579 and "#" is automatically deleted when a construction access user credential is
added to the lock, or a new programming credential is created, or the lock is programmed with the SUS.

CONSTRUCTION ACCESS MODE

AD-200 Offl ine Lock User Guide
Use the same Master Construction
Credential for all the locks in the
facility.
If you present the fi rst card to a new
lock to create the Master Construction
Credential and the card is not
accepted, the lock has either been
programmed or already has a Master
Construction Credential.
If the Master Construction Credential
cannot be located, or to put the lock
back into construction access mode,
reset the lock to factory settings. See
Reset To Factory Defaults on page 11
for more information.