Construction Access Mode; Create The Master Construction Credential - Locks With Card Readers; Add Construction Access Mode User Credentials - Locks With Card Readers; Cancel Construction Access Mode - Schlage AD-400 Instruction Manual

Adaptable series networked wireless lock user guide
Hide thumbs Also See for AD-400:
Table of Contents

Advertisement

AD-400 /AD-401 Networked Wireless Lock User Guide
Construction Access Mode is used to allow access before the lock is
linked to a PIM400, and/or for testing purposes before linking.
Construction Access Mode requires a credential other than a PIN.
• Enabled by default.
• The lock will remain in Construction Access Mode until the mode
is cancelled as described below.
• No audits are captured while the lock is in Construction Access Mode.
Create the Master Construction Credential - Locks with
Card Readers
!
The fi rst card presented to a new lock while pressing
the Schlage button automatically becomes the Master
Construction Credential!
1. Press and hold the Schlage button while presenting a credential.
2. This credential becomes the Master Construction credential and
is used to program construction access.
3. The Schlage button will blink green on the left and right as
confi rmation.
After you have created the Master Construction Credential, you can
then use that card to add construction access mode user credentials.
The Master Construction Credential will not grant access. It is used only to add additional
credentials.

Add Construction Access Mode User Credentials - Locks with Card Readers

1. Present the Master Construction Credential to the lock. The Schlage button will light solid green
for 20 seconds.
2. Present the user credential to be added within twenty (20) seconds. The user credential will be
added to the lock database.
3. The Schlage button will blink green on the left and right as confi rmation.
4. Repeat steps 1 and 2 for additional user credentials.
Credentials added using the Master Construction Credential will have normal 24/7 access.

Cancel Construction Access Mode

Do one of the following:
• Reset the lock to factory settings. See Reset to Factory Default Settings on page 9 for more
information.
• Link the lock to a PIM400. See Link to a PIM400 on page 7 for more information.
!
When construction access mode is cancelled, the Master Construction Credential and all
other credentials added using the Master Construction Credential will no longer function.

CONSTRUCTION ACCESS MODE

6
TIPS
Use the same Master
Construction Credential for
all the locks in the facility.
If the fi rst card presented
to a new lock to create
the Master Construction
Credential is not accepted,
the lock has either been
programmed or already
has a Master Construction
Credential.
If the Master Construction
Credential cannot be
located, or to put the lock
back into construction
access mode, reset the
lock to factory settings. See
Reset to Factory Default
Settings on page 9 for more
information.