1U03 1782
Model: ECW-300/360
SAFETY INSTRUCTIONS
Before installation and operation, read these instructions carefully
and use this product only in the manner described by the
manufacturer in the operation manual.
The instruction shown below are used to alert you to potential
personal injury and property damage hazards.
There are three hazard classifications based on potentially
dangerous situations.
Obey all safety instructions that show these symbols to avoid
possible injury, death and property damage.
WARNING:
WARNING indicates a potentially
hazardous situation which, if not
avoided, could result in death or
serious injury.
CAUTION:
CAUTION indicates a potentially
hazardous situation which, if not
avoided, may result in minor or
moderate injury.
CAUTION:
CAUTION used without the safety
alert symbol indicates a potentially
hazardous situation which, if not
avoided, may result in property
damage.
NOTE: The safety instructions are explained with the following
pictographic symbols.
means prohibition. It indicates actions, if any,
that mustn't be done.
means forcible execution. It indicates actions, if
any, that must be done.
WARNING
1. TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
a) Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer.
b) Before servicing or cleaning unit, switch power
off at service panel and lock the service
disconnecting means to prevent power from being
switched on accidentally. When the service
disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag,
to the service panel.
2. To reduce the risk of fire or electric shock, do not
use this product with any solid-state speed control
device.
3. TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
a) Installation work and electrical wiring must be
done by a qualified person(s) in accordance with
all applicable codes and standards, including fire-
rated construction.
1. Preparation
WARNING:
• If the range hood is not installed properly, it could become detached
and fall.
• Ensure that the metal duct does not touch other metal housing
materials, otherwise fire or electric shock could result.
1
According to the conditions where
Round duct
(For vertical discharge)
the range hood is installed,
(ECW-300=6"/ECW-360=7")
determine whether it will be
discharged vertically or horizontally
Roof cap
(ECW-300: 6" round duct, ECW-
360: 7" round duct). For vertical or
horizontal discharge, run duct work
between the hood location and the
Soffit
roof cap or wall cap.
Wall cap
For best result in either direction,
use a minimum number of
transitions and elbows. Be sure to
Round duct
(For holizontal discharge)
attach a roof cap or wall cap to
(ECW-300=6"/
avoid rain/wind entry.
Range hood
ECW-360=7")
CAUTION:
• Install the range hood unit on a wall where durable
enough to support its weight. Otherwise, it may be
detached and fall down.
Reinforce the wall with some wood panel if necessary.
B
2
Referring to the figure right,
arrange the end of 6" or 7" round
A
duct just above the exhaust port of
the range hood unit.
Range hood
A
B
Duct
ECW-300
5-5/16"
1"
1-3/16"~
ECW-360
5-7/8"
3-5/16"
1-15/16"
(Unit : inch)
3
Referring to "DIMENSIONS" above, insert
1/4"
2 supplied wood screws into the mounting
wall for the left and right keyholes of the
hanger. Allow about 1/4" space between
the wall and screw-heads for hanging.
2. Range Hood Mounting
CAUTION:
• Wear working gloves to avoid injury.
1
(1) Installing hanger
Put the supplied hanger
on the hood top, and fix it
using screws attached on
the top plate.
(2) Installing exhaust port
Detach the tape on the
ECW-300
exhaust port, then with
Tape
paying attention to the
shutter opening direction,
fix it using screws
attached on the top plate.
Shutter opening
direction
Exhaust port
INSTALLATION MANUAL
b) Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney)
of fuel burning equipment to prevent back drafting.
Follow the heating equipment manufacturer's
guidelines and safety standards such as those
published by the National Fire Protection
Association (NFPA), and The American Society
for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code
authorities.
c) When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
d) Ducted fans must always be vented to the
outdoors.
e) This unit is designed for ducted or ductless
installation. When ductless kit part numbers
FDK-ECW300 (for model ECW-300), FDK-
ECW360 (for model ECW-360) is installed, this
unit is certified ductless. The end user is
responsible to ensure compliance with all Federal,
State and Local Environmental and Fire codes.
4. TO REDUCE THE RISK OF FIRE, USE ONLY
METAL DUCTWORK.
5. This unit must be grounded.
6. Check that the hood is correctly installed, since
incorrect installation could result in the range hood
becoming detached and falling off.
7. Connect only to an AC120 Volt power source or
the range hood could result in fire, electric shock,
and damage.
CAUTION
1. For general ventilating use only. Do not use to
exhaust hazardous or explosive material and
vapors.
2. To reduce the risk of fire and to properly exhaust
air, be sure to duct air outside. Do not vent exhaust
air into spaces within walls or ceilings or into attics,
crawl spaces, or garages.
3. Read specification label on this product for further
information and requirements.
4. Use only for the purpose of kitchen ventilation.
5. Do not install this range hood in the bathroom or
in other wet rooms since electrical shock and
damage may result.
6. Fasten the filter and other parts securely. Incorrect
attachment may result in personal injury or
property damage.
7. Keep your hands and other objects away from
the fan while it is in motion. The range hood may
injure you or damage itself.
2
Detach the rectifier
Loosen 2 screws
to remove the filter
baffle panel by
loosening 2 fixing
screws, sliding it to
dislocate the keyholes
from the screws, and
3
disengaging it from
Filter
the catches.
3
Detach the filters by
turning the fixing
knobs counter-
clockwise, and
disengaging them
from the supporting
2
Rectifier baffle panel
groove.
4
With inserting the exhaust
port into the duct, hook
both the left and right
keyholes of the hanger on
the screws provided in
"Preparation" step 3.
Tighten screws
to fix
5
Tighten both the left and
right screws, and fix the
Center line
range hood securely
adding 4 more supplied
washer head wood
screws to the holes on
the hanger and back of
the range hood.
6
Make the duct joint secure
and air-tight using non-
flammable tape such as duct
tape, etc. (Not supplied)
Non-flammable tape
3. Connecting Power Supply Wires
WARNING:
• Electrical wiring should be done by a qualified person(s) in accordance
with all applicable codes and standards, including fire-rated
construction. An unqualified person doing the work could result in
fire, electric shock or injury.
Hanger
• This range hood uses 120V AC. Do not connect to other voltage since
fire, electric shock or damage could result.
ECW-360
1
Remove the nut from the conduit
connector at the end of power wiring.
WARNING:
Be sure to switch OFF the power
at service panel before wiring.
Range Hood
NAMES OF PARTS
Duct Cover
Hanger
Control Switches
Fan
Filter
Rectifier Baffle Panel
DIMENSIONS
ECW-300
1"
3-3/4"
11"
∅5-7/8"
13/16"
13/16"
30"
24"
ECW-360
2-5/8"
5-7/8"
17"
∅6-15/16"
13/16"
13/16"
36"
24"
INSTALLATION
2
Remove each screw fixing the
wire cover and detach it.
ECW-300
Wire cover
Loosen 2 screws
to remove the
3
Connect the
rectifier baffle panel
conduit through
the connecting
hole of the
enclosure using
the nut previously
removed.
Hanger
4
Connect wires tightly and securely
using wire connectors
(not supplied).
Connect the electrical
wires as follows:
• Black to Black
• White to White
• Green to Green
5
Replace the wire cover with the
screw(s) removed previously.
Make sure that all wires are
connected properly and
enclosed inside of the wiring
compartment.
4. Attaching Duct Cover
1
Referring to "DIMENSIONS" and
"RANGE HOOD LOCATION" above,
calculate the duct cover height
necessary to cover between the
range hood top and ceiling.
Conduit
(Not supplied)
2
For height adjustment, loosen 3
wing-bolts of the duct cover and pull
the inside slide cover up to the height
calculated.
3
Nut
Tighten 3 wing-bolts securely to fix
(Not supplied)
the inside slide cover.
ECW-300
Pilot Lamp
Lamp Switch
OFF Switch
High Switch
Low Switch
Medium Switch
120V
60Hz
ECW-360
120V
60Hz
Unit: inch (mm)
• Screw
M5.1×45
Four (4) pcs.
• Wood Screw
M4.5×45
Two (2) pcs.
• Screw M4×10
Two (2) pcs.
9-1/16"
RANGE HOOD LOCATION
18"
4-∅3/8" Holes for mounting range hood
1
The range hood must be installed just above the
cooktop.
2
The minimum distance from the cooking surface
to the bottom of the range hood must be 24".
3
The total weight of the range hood units are as
follows;
4
Power requirements are:
ECW-300: AC120 V, 60 Hz, 2.5 Amp
ECW-360: AC120 V, 60 Hz, 3.0 Amp
WARNING:
• Check that the hood is correctly installed, since incorrect installation could
result in the detachment of the range hood and the unit could fall down.
CAUTION:
15-1/16"
18"
• To protect hands from injury, wear working gloves when installing the range
4-∅3/8" Holes for mounting range hood
hood.
4
Set the duct cover on the range hood unit, and fix it to the range
hood unit using 2 screws supplied.
ECW-360
Screw
Screw
Wire cover
Conduit
Duct cover
Nut
1
Assembly
Attach the filters and rectifier baffle panel referring to the steps
described in "2. Range Hood Mounting".
Two 50 Watt halogen light bulbs (not supplied) can be mounted in
this range hood.
Prior to function check, install light bulbs (PAR20 bulb, with base
diameter 26 mm: medium base), rated 120 V - 50 Watt or below.
The following light bulbs are recommended for this range hood.
Wire connector
• GE Model No. 50PAR20H/FL25
• SYLVANIA Model No. 50PAR20/HAL/DL/NFL
Turn the lamps clock-wise to install.
ECW-300
Hook
2
Check
ECW-360
(1) Turn on the power to the range hood.
Wire cover
(2) Make sure that the switchs and light operate correctly.
Refer to page 4 of the Operation Manual.
(3) Make sure that the range hood functions properly and it has
no abnormal noises and/or vibration.
Screw
Wire cover
Screw
6. Explanation to the End User
(1) Referring to the Operation Manual, explain the operation of this
range hood to the end user.
Wing-bolt
(2) The Installation Manual and Operation Manual should be given to
the end user.
2
Loosen
3
Fix
CIRCUIT DIAGRAM
Lamp Switch
Fan Switch
Motor
Connector
Pilot Lamp
Connector
Black
White
Grey
Yellow
Black
Lamp 50W
Yellow
Yellow
White
White
Black
Black
Connector
Connector
Connector
White
White
Black
Black
Lamp 50W
Connector
Capacitor
Black
Grey
Grey
White
Purple
Purple
Green
Lamp Switch
Fan Switch
Connector
Pilot Lamp
Connector
Black
White
Grey
Yellow
Black
Lamp 50W
Motor
Yellow
Yellow
White
White
Black
Black
Connector
Connector
Connector
White
White
Black
Black
White
Lamp 50W
Connector
Black
Capacitor
Grey
Grey
Green
Purple
Purple
ACCESSORIES
• Hanger
One (1) pc./ea.
(For ECW-300)
(For ECW-360)
• Exhaust Port
One (1) pc./ea.
24"(minimum)
ECW-300 50.7 lbs. (23kg)
ECW-360 70.5 lbs. (32kg)
Cook top
Hanger
Hanger
Duct cover
5. Assembly and Check
Filter
Rectifier baffle panel
Bulb
(Not supplied)
Push to turn ON
Need help?
Do you have a question about the ECW-300 and is the answer not in the manual?
Questions and answers